RAID Summary
The C220 M3 LFF server has a 4-drive backplane.
■ Intel RSTe, LSI ROM1, and LSI ROM15 embedded RAID upgrade options support up to 4 drives.
■ Mezzanine card (UCSC-RAID-11-C220) supports up to 4 drives.
■ Mezzanine card (UCSC-RAID-MZ-220) supports up to 4 drives.
■ SAS 9266-8i and SAS 9266CV-8i PCIe cards support up to 4 drives.
■ LSI MegaRAID SAS 9285CV-8e supports up to 8 external SAS ports (240 external drives).
See Table 33 for a summary of the supported RAID configuration options.
NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the
embedded RAID upgrade options, you will have an embedded SATA-only RAID
controller that supports up to four SATA-only drives (RAID 0, 1, 10)
Table 33 Supported RAID Configurations
1
Server
#
CPUs
Embedded
RAID
Mezz
RAID
2
Internal
PCIe RAID
#1
3
Internal
PCIe
RAID #2
4
External
PCIe
RAID
5
# Drives
Supported
PCIe Slots
6
1 2
C220 M3 LFF 1 Enabled
Not
allowed
7
Not
allowed
Not
allowed
Not
allowed
4 internal A U
C220 M3 LFF 1
Not
allowed
Not
allowed
Installed
slot 1
(default)
Not
allowed
Card
absent
4 internal O U
C220 M3 LFF 1
Not
allowed
Not
allowed
Card
absent
Not
allowed
Installed
slot 1
0 internal
240
external
O U
C220 M3 LFF 1
Not
allowed
Not
allowed
Installed
slot 1
(default)
Not
allowed
Installed
in slot 2
0 internal
240
external
O O
C220 M3 LFF 2 Enabled
Not
allowed
Not
allowed
Not
allowed
Not
allowed
4 internal A A
C220 M3 LFF 2
Not
allowed
Installed
Not
allowed
Not
allowed
Card
absent
4 internal A A
C220 M3 LFF 2
Not
allowed
Not
allowed
Installed
slot 2
(default)
Not
allowed
Card
absent
4 internal A O
C220 M3 LFF 2
Not
allowed
Card
absent
Card
absent
Not
allowed
Installed
slot 1 or
slot 2
0 internal
240
external
A A
C220 M3 LFF 2
Not
allowed
Installed
Not
allowed
Not
allowed
Installed
slot 1 or
slot 2
4 internal
240
external
A A