Datasheet
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
20
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU Configurations
Mezzanine cards are not supported for 1-CPU configurations, Therefore, only the following RAID
controllers are supported for single-CPU configurations:
■ Embedded RAID (on motherboard)
■ LSI MegaRAID SAS 9266-8i (PCIe slot 1 only)
■ LSI MegaRAID SAS 9266CV-8i (PCIe slot 1 only)
■ LSI MegaRAID SAS 9285CV-8e (PCIe slot 1 only)
RAID Configuration Options (not available for embedded RAID)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting (for the following PIDs only):
■ UCS-RAID-9266-NB
■ UCS-RAID-9266CV
■ UCSC-RAID-11-C220
■ UCSC-RAID-MZ-220
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in
Table 5
NOTE: PCIe slot 2 is not supported for 1-CPU configurations
Table 7 Available Plug-In PCIe Card RAID Options (continued)
Product ID (PID) PID Description