Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) CISCO SYSTEMS 170 WEST TASMAN DR SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV B.
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . .
OVERVIEW OVERVIEW The Cisco® UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database. Building on the success of the Cisco UCS C200 M2 rack server, the enterprise-class UCS C220 M3 server further extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel® E5-2600 series product family CPUs that deliver significant performance and efficiency gains.
DETAILED VIEWS Chassis Rear View Figure 2 shows the external features of the rear panel.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 8.
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Storage controllers Description ■ Embedded RAID (3 Gbs) • Embedded SATA-only RAID controller, supporting up to four SATA-only drives (RAID 0, 1, 10) • Intel Rapid Storage Technology Enterprise (RSTe) RAID upgrade, supporting up to four SAS+SATA drives (RAID 0, 1, 10). • LSI ROM1 RAID upgrade, supporting up to four SAS+SATA drives (RAID 0, 1, 10). • LSI ROM15 RAID upgrade, supporting up to four SAS+SATA drives (RAID 0, 1, 5, 10).
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Interfaces Description ■ Rear panel • One RJ45 serial port connector • Two USB 2.
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C220 M3 High-Density LFF Rack Server: 8 ■ STEP 1 VERIFY SERVER SKU, page 9 ■ STEP 2 SELECT CPU(s), page 10 ■ STEP 3 SELECT MEMORY, page 12 ■ STEP 4 SELECT RAID CONFIGURATION, page 16 ■ STEP 5 SELECT HARD DISK DRIVES (HDDs), page 22 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 24 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26 ■ STEP 8 ORDER POWER SUPPLY, page 29 ■ STEP 9 SELECT AC POWER COR
CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID (PID) of the server as shown in Table 2. Table 2 PID of the C220 M3 High-Density LFF Rack Base Server Product ID (PID) UCSC-C220-M3L Description UCS C220 M3 LFF, no CPU, memory, HDD, power supply, SD card, or PCIe cards, with rail kit The Cisco C220 M3 server: ■ Includes one tool-less rail kit ■ Does not include power supply, CPU, memory, hard disk drives (HDDs), SD card, or plug-in PCIe cards.
CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel E5-2600 series processor family CPUs ■ Intel C600 series chipset ■ Cache size of 10, 15, or 20 MB Select CPUs The available CPUs are listed in Table 3. Table 3 Available Intel CPUs: E5-2600 Series Processor Family CPUs Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 UCS-CPU-E5-2690 E5-2690 2.
CONFIGURING the SERVER Approved Configurations (1) 1-CPU configurations: ■ Select any one CPU listed in Table 3. (2) 2-CPU Configurations: ■ Select two identical CPUs from any one of the rows of Table 3 on page 10. Caveats ■ You can select either one processor or two identical processors. ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 10).
CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 3 12 DIMMs — Clock speed: 1333 or 1600 MHz — Ranks per DIMM: 1, 2, or 4 — Operational voltage: dual voltage capable (1.5 V or 1.35 V) — Registered or unbuffered ECC DDR3 DIMMs (RDIMMs or UDIMMs) or load-reduced DIMMs (LRDIMMs) Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 3.
CONFIGURING the SERVER Select DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel.
CONFIGURING the SERVER ■ Select 2, 4, 6, or 8 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table. Total Number of DIMMs ■ CPU 1 DIMM Placement in Channels (for identical DIMMs) Blue Slots Black Slots 2 (A1, B1) 4 (A1,B1); (C1,D1) 6 (A1,B1); (C1,D1) (A2,B2) 8 (A1,B1); (C1,D1) (A2,B2); (C2,D2) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 13.
CONFIGURING the SERVER Caveats ■ For optimum performance, do not mix DIMMs with different frequencies. If you mix DIMM frequencies, the system defaults to the lower frequency. ■ Do not mix RDIMMs and LRDIMMs ■ DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically. ■ The server supports 1 or 2 DIMMs per channel for single- or dual-rank RDIMMs. ■ The server supports 1 or 2 DIMMs per channel for quad-rank LRDIMMs.
CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10) NOTE: When creating a RAID volume, follow these guidelines: ■ Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs NOTE: The number of RAID gr
CONFIGURING the SERVER Select RAID Options Select as follows (these choices are dependent on the number of CPUs installed): ■ One embedded RAID upgrade option, or ■ One mezzanine RAID controller, or ■ One mezzanine RAID controller and one external RAID controller, or ■ One internal RAID controller, or ■ One internal RAID controller and one external RAID controller NOTE: For all valid combinations of embedded RAID, mezzanine RAID, and internal/external RAID controller combinations, see RAID Summary
CONFIGURING the SERVER Table 6 Available Mezzanine Card RAID Options (continued) Product ID (PID) PID Description UCSC-RAID-MZ-220 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported), operating at 6 Gbs. ■ Supports up to eight internal SAS+SATA drives (limited to four drives for the C220 M3 LFF chassis). SAS and SATA drives can be mixed.
CONFIGURING the SERVER Table 7 Available Plug-In PCIe Card RAID Options (continued) Product ID (PID) PID Description UCS-RAID-9285CV-E LSI MegaRAID SAS 9285CV-e (RAID 0, 1, 5, 6, 10) ■ Supports eight external SAS ports (up to 240 external drives). NOTE: For SAS 9285CV-8e external drive enclosure support, see the compatibility list (enclosure section) at the following link: http://tinyurl.
CONFIGURING the SERVER Table 7 Available Plug-In PCIe Card RAID Options (continued) Product ID (PID) PID Description RAID Configuration Options (not available for embedded RAID) R2XX-SRAID0 Enable Single Disk Raid 0 Setting (for the following PIDs only): ■ UCS-RAID-9266-NB ■ UCS-RAID-9266CV ■ UCSC-RAID-11-C220 ■ UCSC-RAID-MZ-220 R2XX-RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive.
CONFIGURING the SERVER Select an embedded RAID option from Table 5 on page 17, or one internal or external drive PCIe RAID controller or one of each from Table 7 on page 18. You may also select an appropriate optional RAID configuration listed in Table 7 on page 18 (2) 2-CPU Configurations Select an embedded RAID option from Table 5, or one mezzanine RAID controller from Table 6 on page 17, or one internal or external drive PCIe RAID controller or one of each from Table 7 on page 18.
CONFIGURING the SERVER STEP 5 SELECT HARD DISK DRIVES (HDDs) The standard disk drive features are: ■ 3.5-inch large form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 8. Table 8 Available Hot-Pluggable Sled-Mounted HDDs PID Description Drive Type Capacity UCS-HDD3TI2F214 3 TB SAS 7.2K RPM 3.5 inch HDD SAS 3 TB UCS-HDD2TI2F213 2 TB SAS 7.2K RPM 3.5 inch HDD SAS 2 TB UCS-HDD1TI2F212 1 TB SAS 7.2K RPM 3.
CONFIGURING the SERVER Approved Configurations (1) Onboard RAID, mezzanine cards, and internal drive plug-in RAID controllers ■ If you have not selected an onboard RAID upgrade option (Intel RSTe, LSI ROM1, or LSI ROM15), a mezzanine card, or a plug-in RAID controller for internal drives (LSI MegaRAID SAS 9266-8i or LSI MegaRAID SAS 9266CV-8i), you may select up to 4 SATA-only drives, which will be controlled with the embedded SATA-only RAID controller.
CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCie card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards are listed in Table 9.
CONFIGURING the SERVER Approved Configurations (1) No RAID controller plug-in card ■ If you did not choose a plug-in RAID controller (for example, you are using embedded RAID or a mezzanine RAID controller), you can select up to one PCie option card (for 1-CPU systems) or two PCie option cards (for 2-CPU systems) listed in Table 9 on page 24.
CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Table 10 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters.
CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP+ modules are listed in Table 11. Table 11 Available SFP Modules Product ID (PID) PID Description SFP-10G-SR 10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring DS-SFP-FC8G-SW 8 Gbit SFP+ Module 850 nm, multimode, SR, 3.
CONFIGURING the SERVER Figure 4 28 Network Card Connections Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLY The C220 M3 LFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply. A fully loaded server might need to be powered with two 450 W or two 650 W power supplies (see Table 12). Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.
CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD(s) Using Table 13, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 13 Available Power Cords Product ID (PID) PID Description SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Argentina Images 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.
CONFIGURING the SERVER Table 13 Available Power Cords Product ID (PID) PID Description CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Images Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 ) 186575 Plug: I/3G (CEI 23-16) CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 14 to order a cable management arm.
CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) You can order one optional preloaded 16 GB Cisco Flexible Flash secure digital (SD) card. This SD card contains preloaded software for simplified server operation. The ordering information is listed in Table 16. Table 16 Secure Digital (SD) Card (preloaded with software) Product ID (PID) PID Description UCSC-SD-16G-C220 16GB SD Card for C220 servers See Figure 5 on page 48 for the location of the SD cards.
CONFIGURING the SERVER STEP 13 ORDER USB 2.0 DRIVE (OPTIONAL) You can order one optional USB 2.0 drive. The USB drive ordering information is listed in Table 18. Table 18 USB 2.0 Drive Product ID (PID) PID Description UCS-USBFLSH-S-4GB 4GB Flash USB Drive (shorter length) for all servers except C260 See Figure 5 on page 48 for the location of the USB connector.
CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM Several operating systems are available from which to choose. Select one of the operating systems shown in Table 19.
CONFIGURING the SERVER Table 19 38 Operating Systems (continued) PID Description Product ID (PID) VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Required VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Required VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Required VMW-VS5-ENT-1A VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Required VMW-VS5-ENT-2A VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support
CONFIGURING the SERVER STEP 15 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 20.
CONFIGURING the SERVER STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE You can select from a variety of value-added software listed in Table 21.
CONFIGURING the SERVER STEP 17 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media.
CONFIGURING the SERVER SMARTnet for UCS Hardware Only Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. See Table 24.
CONFIGURING the SERVER You can choose a service listed in Table 26.
CONFIGURING the SERVER Table 27 Drive Retention Service Options Service Description Service Program Name SMARTnet for UCS Service with Drive Retention UCS DR SMARTnet for UCS HW ONLY+Drive Retention UCS HW+DR Service Level GSP Service Level Product ID (PID) UCSD7 24x7x4 Onsite CON-UCSD7-C220M3LF UCSD7 8x5xNBD Onsite CON-UCSD5-C220M3LF UCWD7 24x7x4 Onsite CON-UCWD7-C220M3LF UCWD5 8x5xNBD Onsite CON-UCWD5-C220M3LF For more service and support information, see the following URL: http://ww
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M3 LFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 28. Racks are shipped separately from the C220 M3 LFF server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including the C220 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 28). Table 29 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 63.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C220 M3 chassis with the top cover removed is shown in Figure 5.
SUPPLEMENTAL MATERIAL 7 CPUs and heatsinks (two) 16 Power supplies (two, hot-swappable access through rear panel) 8 Integrated RAID on motherboard, and mini-SAS connectors 17 RTC battery on motherboard 9 Mezzanine RAID card, mini-SAS connectors SAS1 and SAS2 18 Software RAID 5 header (RAID key). CPUs and DIMMs Physical Layout Each CPU has four DIMM channels: ■ CPU1 has channels A, B, C, and D ■ CPU2 has channels E, F, G, and H Each DIMM channel has two banks: bank 1 and bank 2.
SUPPLEMENTAL MATERIAL Figure 6 Physical Layout of CPU DIMM Channels and Banks C1 C2 D1 D2 CPU1 Front of Server B2 B1 A2 A1 G1 G2 H1 H2 F2 F1 E2 E1 50 331707 CPU2 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should consider the following items: ■ ■ Each channel has two DIMM slots (for example, channel A = slots A1 and A2). — A channel can operate with one or two DIMMs installed. — If a channel has only one DIMM, populate slot 1 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically.
SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the C220 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Do not mix: — DIMMs with different sizes or clock rates in a bank — RDIMMs and LRDIMMs — ECC and non-ECC DIMMs ■ There are blue and black DIMM slots. Populate blue slots first.
SUPPLEMENTAL MATERIAL Supported DIMM Populations The supported DIMM populations are listed in Table 32.
SUPPLEMENTAL MATERIAL Low-Voltage DIMM Considerations The C220 M3 server can be ordered with dual-voltage (1.5/1.35 V) DIMMs only. Note the following considerations: 54 ■ Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size. ■ Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
SUPPLEMENTAL MATERIAL RAID Summary The C220 M3 LFF server has a 4-drive backplane. ■ Intel RSTe, LSI ROM1, and LSI ROM15 embedded RAID upgrade options support up to 4 drives. ■ Mezzanine card (UCSC-RAID-11-C220) supports up to 4 drives. ■ Mezzanine card (UCSC-RAID-MZ-220) supports up to 4 drives. ■ SAS 9266-8i and SAS 9266CV-8i PCIe cards support up to 4 drives. ■ LSI MegaRAID SAS 9285CV-8e supports up to 8 external SAS ports (240 external drives).
SUPPLEMENTAL MATERIAL Table 33 Supported RAID Configurations1 (continued) Server C220 M3 LFF # Embedded CPUs RAID 2 Not allowed Mezz RAID2 Not allowed Internal PCIe RAID #13 Installed slot 2 (default) Internal PCIe RAID #24 Not allowed External # Drives PCIe Supported RAID5 Installed in slot 1 4 internal 240 external PCIe Slots6 1 2 O O Notes . . . 1. You cannot mix RAID types. You can use either embedded RAID, mezzanine RAID, or PCIe RAID, but only one at a time. 2.
SUPPLEMENTAL MATERIAL RAID Option ROM (OPROM) Settings The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in Figure 7.
SUPPLEMENTAL MATERIAL Upgrade and Servicing-Related Parts This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See Table 34. Table 34 Upgrade and Servicing-related Parts for UCS C220 M3 LFF Server Spare Product ID (PID) Description UCSC-BBLKD-L= 3.
SUPPLEMENTAL MATERIAL 2. If your server contains an LSI MegaRAID SAS 9266-8i RAID controller card with battery backup (UCS-RAID-9266), the card contains a battery backup unit (UCS-RAID-BBU), which can be replaced. If your server contains an LSI MegaRAID SAS 9266-8i RAID controller card without a battery backup unit (UCS-RAID-9266NB), the card does not contain a battery backup unit (UCS-RAID-BBU); however, you can retrofit the card with a battery backup if desired.
SUPPLEMENTAL MATERIAL Thermal Grease (with syringe applicator) for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink. Instructions for applying thermal grease are found at: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864 CAUTION: Use only the thermal grease specified for this server (UCS-CPU-GREASE2=).
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 8) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 35. Table 35 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view - door closed 62 Front view - door open Front view - door removed Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
SUPPLEMENTAL MATERIAL KVM CABLE The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server. The KVM cable ordering information is listed in Table 36.
SUPPLEMENTAL MATERIAL Motherboard USB and SD Ports, and RAID Card Backup Location The C220 M3 LFF motherboard has a general-purpose USB socket, and two SD sockets as shown in Figure 11. The mounting location for the RAID SuperCap data cache power backup module is also shown.
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 37 UCS C220 M3 LFF Dimensions and Weight Parameter Value Height 1.7 in. (4.32 cm) Width 16.92 in.(43.0 cm) Depth 29.7 in. (75.5 cm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 6 in. (152 mm) Weight Maximum (4 HDDs, 2 CPUs, 16 DIMMs, 2 power supplies) 37.1 lbs (16.8 kg) Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply) 28.5 lbs (12.9 kg) Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply) 23.
TECHNICAL SPECIFICATIONS Table 38 UCS C220 M3 LFF 450 W Power Supply Specifications (continued) Description Specification Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. The general power specifications for the C220 M3 LFF server 650 W power supply are listed in Table 38.
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C220 M3 server are listed in Table 40. Table 40 UCS C220 M3 Environmental Specifications Parameter Minimum Temperature operating 41 to 104° F (5 to 40° C) derate the maximum temperature by 1°C per every 305m of altitude above sea level Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) nonoperating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.
TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 41. Table 41 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No.
TECHNICAL SPECIFICATIONS 70 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)