Power LED Green Status is as follows:
• Steady—Cisco Integrated Management Controller
and CPU are both operating normally
• Blinking—CPU is operating normally and Cisco
Integrated Management Controller is booting up
Amber Status is as follows:
• Steady—Cisco Integrated Management Controller is
operating normally and the CPU is powered down
• Blinking —Cisco Integrated Management
Controller is in the process of booting up and the
CPU is powered down
1. This is memory installed on the outermost DIMM slot.
2. This is the middle DIMM slot.
3. This is the innermost DIMM slot.
Table 5 LED States for the Single-Wide E-Series Servers
LED Color Indicates
HDD 0 ACT Green Status of hard drive activity is as follows:
• Steady—Hard Drive is present
• Blinking—Activity
• Off—Inactive or there is no power supplied to the CPU
HDD0 FLT Amber The CPU is in use. Fault detected on the hard drive.
Note The SYS LED will still show solid green.
HDD1 ACT Green Status of hard drive activity is as follows:
• Steady—Hard Drive is present
• Blinking—Activity
• Off—Inactive or there is no power supplied to the CPU
HDD1 FLT Amber The CPU is in use. Fault detected on the hard drive.
Note The SYS LED will still show solid green.
Table 4 LED States for the Double-Wide E-Series Servers (continued)
LED Color Indicates