Datasheet
Cisco UCS B420 M3 Blade Server
SUPPLEMENTAL MATERIAL
43
Connectivity Using the Cisco UCS 2208XP Fabric Extender
The connectivity options shown in Figure 11 through Figure 21 are summarized in Table 29.
Table 29 Supported Adapter
1
Combinations Using the 2208XP FEX
2
Notes
1. In the server BIOS and on the motherboard, “Adapter 1,” “Adapter 2,” and “Adapter 3” are labeled as “mLOM,”
“Mezz 1,” and “Mezz 2,” respectively
2. Not all combinations are supported in 2-CPU configurations (see Table 9 on page 17)
Adapter Slot 1 Adapter Slot 2 Adapter Slot 3
Total Available
Bandwidth
2 x 2208 XP
VIC 1240 Not populated Not populated 40 Gb
Figure 11 on page 44
VIC 1240 Not populated VIC 1280 120 Gb
Figure 12 on page 44
Not populated Not populated VIC 1280 80 Gb
Figure 13 on page 45
VIC 1240 Not populated Emulex or QLogic adapter 60 Gb
Figure 14 on page 45
VIC 1240 Port Expander Card for VIC 1240 Not populated 80 Gb
Figure 15 on page 46
Not populated Not populated Emulex or QLogic adapter 20 Gb
Figure 16 on page 47
Not populated Emulex or QLogic adapter Emulex or QLogic adapter 40 Gb
Figure 17 on page 47
VIC 1240 Port Expander Card for VIC 1240 VIC 1280 160 Gb
Figure 18 on page 48
VIC 1240 Not populated Cisco UCS Storage Accelerator 40 Gb
Figure 19 on page 49
VIC 1240
Cisco UCS Storage Accelerator
3
3. This combination requires that both Storage Accelerators be identical.
Cisco UCS Storage Accelerator
3
40 Gb
Figure 20 on page 49
Not populated Cisco UCS Storage Accelerator VIC 1280 80 Gb
Figure 21 on page 50
VIC 1240 Cisco UCS Storage Accelerator VIC 1280 120 Gb
Figure 22 on page 51