Cisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model) CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.
CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 BASE SERVER STANDARD CAPABILITIES and FEATURES . .
OVERVIEW OVERVIEW The Cisco® UCS C22 M3 Rack Server combines economics and a density-optimized feature set from entry level enterprise to SMB with applications such as scale out, virtualization, IT and web infrastructure, VPN servers, file/print servers, and appliances.
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C22 M3 High-Density SFF Rack Server. 1 Chassis Front View 2 3 4 5 6 HDD04 7 8 HDD01 HDD06 HDD05 9 HDD02 HDD07 HDD03 HDD08 10 1 Power button/power status LED 6 Power supply status LED 2 Identification button/LED 7 Network link activity LED 3 System status LED 8 USB 2.
DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER, page 8.
BASE SERVER STANDARD CAPABILITIES and FEATURES Capability/Feature Video Description The Emulex Pilot 3 Integrated Baseboard Management Controller provides video: ■ Matrox G200e video controller ■ Integrated 2D graphics core with hardware acceleration ■ Interfaces Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at 60 Hz ■ 24-bit color depth for all resolutions less than 1600x1200 ■ Up to 256 MB video memory ■ Rear panel • One DB9 serial port connector • Four USB 2.
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C22 M3 High-Density SFF Rack Server: 8 ■ STEP 1 VERIFY SERVER SKU, page 9 ■ STEP 2 SELECT CPU(s), page 10 ■ STEP 3 SELECT MEMORY, page 12 ■ STEP 4 SELECT RAID CONFIGURATION, page 15 ■ STEP 5 SELECT HARD DISK DRIVES (HDDs), page 19 ■ STEP 6 SELECT PCIe OPTION CARD(s), page 21 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 23 ■ STEP 8 SELECT AC POWER CORD(s), page 26 ■ STEP 9 ORDER POWER SUP
CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID (PID) of the server as shown in Table 2. Table 2 PID of the C22 M3 High-Density SFF Rack Base Server Product ID (PID) UCSC-C22-M3S Description UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, or PCIe cards The Cisco C22 M3 server: ■ Includes a rail kit ■ Does not include power supply, CPU, memory, hard disk drives (HDDs), or plug-in PCIe cards.
CONFIGURING the SERVER STEP 2 SELECT CPU(s) The standard CPU features are: ■ Intel Xeon E5-2400 series processor family CPUs ■ Intel C600 chipset ■ Cache size of 10, 15, or 20 MB Select CPUs The available CPUs are listed in Table 3. Table 3 Available Intel CPUs: Xeon E5-24xx Family Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz)1 UCS-CPU-E5-2470 E5-2470 2.30 95 20 8 8.0 1600 UCS-CPU-E5-2450 E5-2450 2.
CONFIGURING the SERVER ■ For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 10). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.
CONFIGURING the SERVER STEP 3 SELECT MEMORY The standard memory features are: ■ ■ Figure 4 12 DIMMs — Clock speed: 1333 or 1600 MHz — Ranks per DIMM: 1 or 2 — Operational voltage: dual voltage capable (1.5 V or 1.35 V) — Registered ECC DDR3 DIMMS (RDIMMS) Memory is organized with three memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 4.
CONFIGURING the SERVER Select DIMMs Select the memory configuration. The available memory DIMMs are listed in Table 4. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel.
CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 13. ■ (1) 2-CPU configuration without memory mirroring: Select from 1 to 6 DIMMs per CPU (2 to 12 DIMMs total). Refer to Memory Population Rules, page 46, for more detailed information. ■ (2) 2-CPU configuration with memory mirroring: Select 2 or 4 DIMMs per CPU (4 or 8 DIMMs total).
CONFIGURING the SERVER STEP 4 SELECT RAID CONFIGURATION The RAID controller choices are: ■ Software RAID, implemented using the C600 chipset built-in SAS RAID controller plus LSI MegaSR (this configuration does not consume a PCIe slot), or ■ Plug-in PCIe controller cards: — LSI MegaRAID 9265CV-8i (with 1 GB TMM data cache and SuperCap for data cache power backup) — LSI MegaRAID 9240-8i — LSI MegaRAID 9220-8i — LSI MegaRAID 9220-4i Cisco can provide factory-configured RAID systems depending on
CONFIGURING the SERVER Table 6 Available Hardware RAID Options Product ID (PID) PID Description RAID Controllers UCS-RAID-9265CV UCSC-RAID-9240-8I UCSC-RAID-9220-8I UCSC-RAID-9220-4i 16 LSI MegaRAID 9265CV-8i (with data cache backup) ■ Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed.
CONFIGURING the SERVER Table 6 Available Hardware RAID Options (continued) Product ID (PID) PID Description RAID Configuration Options (not available for LSI MegaSR software RAID) R2XX-RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting. Requires a minimum of one hard drive. R2XX-RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
CONFIGURING the SERVER — ■ 18 Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is supported and it must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI. So take this into account when populating RAID controller cards. In 2-CPU configurations, there are two PCIe slots available (one full-height slot and one half-height slot).
CONFIGURING the SERVER STEP 5 SELECT HARD DISK DRIVES (HDDs) The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Select Drives The available drives are listed in Table 7. Table 7 Available Hot-Pluggable Sled-Mounted HDDs PID Description Drive Type Capacity A03-D146GC2 146 GB 6Gb SAS 15K RPM SFF SAS 146 GB UCS-HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF SAS 300 GB A03-D300GA2 300 GB 6Gb SAS 10K RPM SFF SAS 300 GB A03-D500GC3 500 GB SATA 7.
CONFIGURING the SERVER Approved Configurations (1) Software RAID (LSI MegaSR) ■ Select up to eight SAS/SATA drives (note that no factory-configured RAID option can be chosen for software RAID). You can mix SAS and SATA drives. (2) LSI MegaRAID 9265CV-8i (with data cache and SuperCap), LSI MegaRAID 9240-8i, and LSI MegaRAID 9220-8i ■ Select up to eight SAS/SATA drives listed in Table 7. You can mix SAS and SATA drives. (3) LSI MegaRAID 9220-4i ■ Select up to four SAS/SATA drives listed in Table 7.
CONFIGURING the SERVER STEP 6 SELECT PCIe OPTION CARD(s) The standard PCIe card offerings are: ■ Converged Network Adapters (CNAs) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Select PCIe Option Cards The available PCIe option cards are listed in Table 8.
CONFIGURING the SERVER Approved Configurations (1) No RAID controller plug-in card ■ If you did not choose a plug-in RAID controller card (for example, you selected software RAID (LSI MegaSR) or no RAID controller at all), you can select up to one PCIe option card listed in Table 8 on page 21 for 1-CPU configurations or up to two cards for 2-CPU configurations.
CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Table 9 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters.
CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP+ modules are listed in Table 10. Table 10 Available SFP Modules Product ID (PID) PID Description SFP-10G-SR 10GBASE-SR SFP+ Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring DS-SFP-FC8G-SW 8 Gbit SFP+ Module 850 nm, multimode, SR, 3.
CONFIGURING the SERVER Figure 5 Network Card Connections Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 25
CONFIGURING the SERVER STEP 8 SELECT AC POWER CORD(s) Using Table 11, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 11 Available Power Cords Product ID (PID) PID Description SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, Argentina Images 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.
CONFIGURING the SERVER Table 11 Available Power Cords Product ID (PID) PID Description CAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy Images Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector C15M (EN60320/C15 ) 186575 Plug: I/3G (CEI 23-16) CAB-9K10A-SW Power Cord, 250VAC 10A MP232 Plug, Switzerland Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.
CONFIGURING the SERVER STEP 9 ORDER POWER SUPPLY The C22 M3 server accommodates one power supply. A lightly loaded server can operate from one 450 W power supply. A fully loaded server might need to be powered with a 650 W power supply (see Table 12). Prior to making a power supply selection, the UCS Power Calculator should be run to determine the right size power supply for your server configuration. A fully configured C22 M3 server may require the 650 W power supply.
CONFIGURING the SERVER STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 13 to order a cable management arm. Table 13 Cable Management Arm Product ID (PID) PID Description UCSC-CMA1 Cable Management Arm for C22 rack servers NOTE: If you order and install a cable management arm, you will need the longest power cable available.
CONFIGURING the SERVER STEP 11 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 12 ORDER OPTIONAL USB 2.0 DRIVES You may order one or two optional USB 2.0 drives. One socket on the motherboard can accommodate the 8 GB drive and you can use any of the external USB 2.0 ports for the 16 GB drive. The 8 GB drive (if ordered) is blank and comes installed on the motherboard. It can be used for a hypervisor or a license dongle. The 16 GB drive (if ordered) comes as a separate item in the shipping box and contains preloaded drivers and utilities.
CONFIGURING the SERVER STEP 13 SELECT OPERATING SYSTEM Several operating systems are available from which to choose. Select one of the operating systems shown in Table 16.
CONFIGURING the SERVER Table 16 Operating Systems (continued) PID Description Product ID (PID) VMWare Server 34 VMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Rqd VMW-VS5-STD-2A VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Rqd VMW-VS5-STD-3A VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Rqd VMW-VS5-STD-4A VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Rqd VMW-VS5-STD-5A VMware vSphere 5 Standard for 1 Processor, 5 Year, Suppor
CONFIGURING the SERVER STEP 14 SELECT OPERATING SYSTEM MEDIA KIT Select the optional operating system media listed in Table 17.
CONFIGURING the SERVER STEP 15 SELECT OPTIONAL VALUE-ADDED SOFTWARE You can select from a variety of value-added software listed in Table 18.
CONFIGURING the SERVER STEP 16 SELECT SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) onsite parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media. ■ Downloads of BIOS, drivers, and firmware updates.
CONFIGURING the SERVER world. As a part of this service, Cisco will assist in issues involving third-party software that have been certified for use on the Cisco Unified Computing System For Cisco UCS servers under Cisco Unified Computing System Manager (UCSM), you get Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades.
CONFIGURING the SERVER Table 21 Drive Retention Service Options Service Description UCS Mission Critical Support Service With Drive Retention UCS Support Service With Drive Retention UCS Warranty Plus With Drive Retention Service Program Name Service Level GSP Service Level Product ID (PID) UC CRIT DR UCMD7 24x7x4 Onsite CON-UCMD7-C22M3S UCMD8 24x7x2 Onsite CON-UCMD8-C22M3S UCSD1 8x5xNBD CON-UCSD1-C22M3S UCSD2 8x5x4 CON-UCSD2-C22M3S UCSD3 24x7x4 CON-UCSD3-C22M3S UCSD4 24x7x2 CON-UC
CONFIGURING the SERVER about Cisco Mission Critical Support Service, please visit Data Center Technical Support and Operations Management CEC site and Service Description or contact your Cisco account Manager. For more service and support information, see this URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 22. Racks are shipped separately from the C22 M3 SFF server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 22). Table 23 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs, page 52.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C22 M3 chassis with the top cover removed is shown in Figure 6.
SUPPLEMENTAL MATERIAL 5 DIMM slots on motherboard (12) 13 Integrated SAS RAID connectors on motherboard (left to right, SCU_Port 0, SCU_Port 1) 6 CPU and heatsinks (2) 14 Software RAID 5 key header on motherboard 7 PCIe riser 1 (PCIe slot 1) 15 RAID SCU option ROM header on motherboard 8 Internal USB 2.
SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks A0 A1 B0 B1 C0 C1 CPU1 Front of Server D0 D1 E0 E1 F0 F1 285209 CPU2 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server 45
SUPPLEMENTAL MATERIAL Memory Population Rules When considering the memory configuration of your server, you should consider the following items: ■ ■ 46 Each channel has two DIMM slots (for example, channel A = slots A0 and A1). — Each channel can operate with one or two DIMMs installed. — If a channel has only one DIMM, populate slot 0 first (the blue slot). When both CPUs are installed, populate the DIMM slots of each CPU identically.
SUPPLEMENTAL MATERIAL Recommended Memory Population This section explains the recommended DIMM population order rules for the C22 M3 server. ■ All DIMMs must be DDR3 DIMMs. ■ Mixing of Registered and Unbuffered DIMMs is not allowed per platform. ■ Do not mix 1333-MHz DIMMs with 1600-MHz DIMMs. Follow Table 24 when populating DIMMs in the server.
SUPPLEMENTAL MATERIAL Supported DIMM Populations The supported DIMM populations are listed in Table 25.
SUPPLEMENTAL MATERIAL Low-Voltage DIMM Considerations The C22 M3 server can be ordered with low-voltage (1.35 V) DIMMs only. Note the following considerations: ■ Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size. ■ Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 8) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 26. Table 26 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view - door closed Front view - door open Cisco UCS C22 M3 High-Density SFF Rack-Mount Server Front view - door removed 51
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
SUPPLEMENTAL MATERIAL Motherboard USB Port The C22 M3 SFF motherboard has one general-purpose USB socket as shown in Figure 10. Figure 10 Motherboard USB Port SYS FAN1 CPU 1 SYS FAN2 PCIe 1 1 SYS FAN3 SYS FAN4 PCIe 2 CPU 2 SYS FAN5 PSU 1 1 Internal USB 2.
SUPPLEMENTAL MATERIAL LED Indicators The server contains LED indicators on the front and rear panels. Their functions are described in the following sections. Front Panel Figure 11 shows the front panel LEDs.
SUPPLEMENTAL MATERIAL Table 27 Front Panel LEDs (continued) LED LED State Meaning System Status Off Undefined On (green) Server is in normal operating condition On (amber) Server is in a degraded operational state. For example: Blinking (amber) Fan Status Temperature Status Power Supply Status Network Link Status ■ Power supply redundancy is lost. ■ CPUs are mismatched. ■ At least one CPU is faulty. ■ At least one DIMM is faulty. ■ At least one drive in a RAID configuration failed.
SUPPLEMENTAL MATERIAL Table 27 Front Panel LEDs (continued) LED Hard Drive Fault Hard Drive Activity LED State Meaning Blinking (green) Activity on any of the LOM ports Off The hard drive is operating properly On (amber) The hard drive has failed Blinking (amber) The hard drive is rebuilding Off There is no hard drive in the hard drive sled (no access, no fault) On (green) The hard drive is ready Blinking (green) The hard drive is reading or writing data Rear Panel Figure 12 shows the re
SUPPLEMENTAL MATERIAL See Table 28 for the functions of the rear panel LEDs. Table 28 Rear Panel LEDs LED LED State Meaning Power Supply Fault Off The power supply is operating normally Blinking (amber) An event warning threshold has been reached, but the power supply continues to operate On (amber) A critical fault threshold has been reached, causing the power supply to shut down (for example, a fan failure or an over-temperature condition).
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 29 UCS C22 M3 Dimensions and Weight Parameter Value Height 1.70 in (43.2 mm) Width 16.93 in.(430 mm) Depth 26.0 in. (660.4 mm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 9 in. (233 mm) Weight Maximum (8 HDDs, 2 CPUs, 12 DIMMs, 1 power supply) 27.78 lbs (12.6 kg) Bare (0 HDD, 0 CPU, 0 DIMM, no power supply) 23.48 lbs (10.
TECHNICAL SPECIFICATIONS NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. The general power specifications for the C22 M3 SFF server 650 W power supply are listed in Table 30. Table 31 UCS C22 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self-ranging, 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal) Maximum AC input current 7.6 A maximum at 100 VAC 3.
TECHNICAL SPECIFICATIONS Table 32 UCS C22 M3 Environmental Specifications Parameter Minimum Temperature nonoperating –40 to 149°F (–40 to 65°C) Humidity (RH) nonoperating, non-condensing 10 to 90% Altitude operating 0 to 3,000 m (0 to 10,000 ft.) Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.) Sound Power level, Measure A-weighted per ISO7779 LWAd (Bels) Operation at 73°F (23°C) 5.
TECHNICAL SPECIFICATIONS Compliance Requirements The regulatory compliance requirements for C-Series servers are listed in Table 33. Table 33 UCS C-Series Regulatory Compliance Requirements Parameter Description Regulatory Compliance Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC Safety UL 60950-1 Second Edition CAN/CSA-C22.2 No.
TECHNICAL SPECIFICATIONS 62 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server