Specifications

Send document comments to ucs-docfeedback@cisco.com
3-28
Cisco UCS C200 Server Installation and Service Guide
OL-20732-02
Chapter 3 Maintaining the Server
Installing or Replacing Components
How to Identify Which Power Supply Model is in Your Server
There are two methods that you can use to identify which power supply is installed in your server:
1. Visually inspect th e power supply at the rear of the server. The new power supply model
R2X0-PSU2-650W-SB has a sticker with the number 650W-SB; the old power supply has no sticker.
2. Use the Cisco Integrated Management Controller (CIMC) GUI to view the power supply model:
a. Use a browser to connect to CIMC using the CIMC IP address.
b. Log in to CIMC using your administrator user name and password.
c. On the CIMC Server tab, click Inventory.
d. On the Inventory pane, click the Power Supplies tab.
e. View the power supply model number in the Product ID column. The new power supply is
listed by the manufacturer’s model number, R2X0-PSU2-650W-SB.
Replacing a PCIe Card (Mass Storage Controllers)
The qualified and supported part numbers for this component are subject to change over time. For the most
up-to-date list of replaceable components, see the following URL and navigate to the page for your server
model and generation:
http://www.cisco.com/en/US/prod/ps10265/ps10493/c-series_part_numbers.html
In addition to the hardware replacement procedure, this section contains the following topics:
Special Installation Instructions For the LSI MegaRAID Battery Backup Unit, page 3-30
Identifying Which Cards Are Installed in Your Server, page 3-32
LSI MegaRAID Card Beep Codes, page 3-32
Note For network adapter PCIe cards, see the “Replacing a PCIe Card (Network Adapters)” section on
page 3-25.
Note If you do not know which cards are installed in your server, see the “Identifying Which Cards Are
Installed in Your Server” section on page 3-32.
Note LSI MegaRAID SAS controller cards are enabled with beep codes that can indicate activity within the
RAID array. See the “LSI MegaRAID Card Beep Codes” section on page 3-32 for more information.
Installing a PCIe card requires that you first remove the riser card assembly from the chassis. To install
or replace a PCIe card, follow these steps:
Step 1 Remove a PCIe card:
a. Power off the server as described in the “Shutting Down and Powering Off the Server” section on
page 3-6.
b. Disconnect all power cords from the power supplies.