Specifications
Send document comments to ucs-docfeedback@cisco.com
3-13
Cisco UCS C200 Server Installation and Service Guide
OL-20732-02
Chapter 3 Maintaining the Server
Installing or Replacing Components
d. Remove the power supply from the bay.
Step 2 Install a new power supply:
a. Insert the new power supply into the bay and push it inward until the release lever clicks and locks.
b. Replace the power cord to the new power supply.
c. Press the Power button to return the server to main power mode.
Figure 3-6 Removing and Replacing a Power Supply
Installing a Fan Tray
The qualified and supported part numbers for this component are subject to change over time. For the most
up-to-date list of replaceable components, see the following URL and navigate to the page for your server
model and generation:
http://www.cisco.com/en/US/prod/ps10265/ps10493/c-series_part_numbers.html
To replace a fan tray, follow these steps:
Step 1 Remove a fan tray:
a. Power off the server as described in the “Shutting Down and Powering Off the Server” section on
page 3-6.
b. Disconnect all power cords from the power supplies.
c. Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Caution If you cannot safely view and access the component, remove the server from the rack.
d. Remove the top cover as described in the “Removing and Replacing the Server Top Cover” section
on page 3-8.
e. Remove the cable cover that sits over the fan tray and set it aside.
Note If your server has an optional LSI battery-backup unit (BBU) mounted to the fan tray, you must
remove the BBU. Remove the three screws that secure the BBU to the bracket on the fan tray
and set the BBU aside. See the
“Special Installation Instructions For the LSI MegaRAID Battery
Backup Unit” section on page 3-30 for more information.
1 Release lever 2 Power supply handle
195726
1 2