Cisco UCS C200 Server Installation and Service Guide
OL-20732-02
Chapter 3 Maintaining the Server
Status LEDs
Rear Panel LEDs
Figure 3-2 shows the names and locations of the rear panel LEDs. A Generation M2 server is shown (the
USB ports and the 10/100 Ethernet management port are in slightly different positions for Generation
M1).
Figure 3-2 Rear Panel LEDs
Table 3-2 describes the possible states and interpretations for the LEDs that are shown in Figure 3-2.
System fault Green—The server is operating properly.
Amber, blinking—An event that requires a service action has been
detected. Investigate other LEDs and check logs to isolate the
problem.
Locator Off—The Locator LED is not in use.
Blue, flashing—The Locator LED/button was pressed and the
Locator LED flashes on the front and rear panels to help you find
the server in a rack.
Power status Off—No AC power is present.
Green, blinking—The server is in standby power mode.
Green—The server is in main power mode.
See the “Connecting and Powering On the Server (Standalone Mode)”
section on page 2-8 for definitions of these power modes.