Specifications

Send document comments to ucs-docfeedback@cisco.com
2-20
Cisco UCS C200 Server Installation and Service Guide
OL-20732-02
Chapter 2 Installing the Server
Configuring BIOS Settings and Updating BIOS Firmware
Step 14 Move the shorting jumper from header pins 1 and 2, back to its default position on pins 2 and 3.
Note If you do not move the jumper, the server forces a recovery of the new BIOS every time that you
power cycle the server.
Step 15 Replace the top cover, replace the server in the rack, replace power cords and any other cables, then
power on the server by pressing the Power button.
Motherboard Jumpers
These jumpers are adjacent to the CMOS battery (see Figure 2-5). This section contains the following
topics:
Clearing the CIMC Admin Password Using Jumper J45, page 2-21
Using the Clear CMOS Jumper J1E6, page 2-22
Clearing the BIOS Admin Password Using Jumper J1E4, page 2-23
Figure 2-5 Service Jumper Locations
1 Jumper J1E6 (clear CMOS) 3 Jumper J45 (clear CIMC password)
2 Jumper J1E5 (BIOS recovery) 4 Jumper J1E4 (clear BIOS password)
199626
1
2
3
4