Troubleshooting guide

Send document comments to ucs-docfeedback@cisco.com
24
Cisco UCS B22 Blade Server Installation and Service Note
OL-27513 -01
Removing a Blade Server Cover
Installing Memory
To install a DIMM into the B22 blade server, follow these steps:
Step 1 Open both DIMM connector latches.
Figure 15 Installing DIMMs in the Blade Server
Step 2 Press the DIMM into its slot evenly on both ends until it clicks into place.
Note Be sure that the notch in the DIMM aligns with the slot. If the notch is misaligned you may damage the
DIMM, the slot, or both.
Step 3 Press the DIMM connector latches inward slightly to seat them fully.
Supported DIMMs
The following table lists the type of DIMMs that Cisco makes available for use with this blade server:
2
2
1
3
1
3
332666
Table 4 Cisco Supported DIMMs for B22 M3 Servers
Cisco Product ID Description
UCS-MR-1X162RY-A 16 GB DDR3 1600 MHz RDIMM PC3-12800 dual rank/Low Voltage
UCS-MR-1X082RY-A 8 GB DDR3 1600 MHz RDIMM PC3-12800 dual rank/Low Voltage
UCS-MR-1X041RY-A 4 GB DDR3 1600 MHz RDIMM PC3-12800 single rank/1.35v/1.5v