Troubleshooting guide
26
Cisco UCS B200 M3 Blade Server Installation and Service Note
OL-26624-01
Working Inside the Blade Server
Figure 17 Replacing the Heat Sink (B200 M3 Shown)
Step 8 Using the syringe of thermal grease provided with replacement CPUs and servers (and available
separately as UCS-CPU-GREASE=, the only exceptions are Cisco UCS C220 M3 and and C240 M3
servers which use UCS-CPU-GREASE2= instead), add 2 cubic centimeters of thermal grease to the top
of the CPU where it will contact the heat sink. Use the pattern shown in Figure 18. This should require
half the contents of the syringe.
Figure 18 Thermal Grease Application Pattern
Caution The thermal grease has very specific thermal properties, and thermal grease from other sources should
not be substituted. Using other thermal grease may lead to damage.
Step 9 Replace the heat sink. See Figure 17, callout 4.
331372
5
4
5
5
5
2
1
3
1
2
3
4
334295