Working Inside the Blade Server
Figure 14 Protective Cap Removal
To install a CPU and heat sink, follow these steps:
Step 1 Release the catch on the pick and place tool by pressing the handle/button.
Step 2 Remove the new CPU from the packaging, and load it into the pick and place tool as follows (see
Figure 15):
a. Confirm that the pedestal is set up correctly for your processor. The pedestal ships configured with
the markings “LGA2011-R0” facing upward, and this is the correct orientation.
b. Place the CPU on the pedestal. The CPU corners should fit snugly at the pedestal corners and the
notches should meet the pegs perfectly.
c. Place the CPU pick and place tool on the CPU pedestal aligned with the A1 arrow pointing to the
A1 registration mark on the pedestal.
d. Press the button/handle on the tool to grasp the CPU.
e. Lift the tool and CPU straight up off of the pedestal.