Specifications
AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router
Removing and Replacing an AC PEM
19
AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router
78-13996-01 Rev. B0
Figure 12 Installing the AC PEM
Step 8 Position the second replacement AC PEM in the power bay and push it forward. Verify that it goes all
the way in and makes a secure connection with the backplane. Tighten the captive screws to secure the
unit to the chassis (Figure 12).
Caution Although one AC PEM can supply sufficient power for a fully configured chassis, run the
Cisco uBR10012 router with two AC PEMs installed, because this provides redundant power
support.
Step 9 Plug the AC-input power cable into the power receptacle on the front panel of each AC PEM.
Step 10 Route the power cable up the front of the AC PEM and clip it into the two plastic retaining clips attached
to the surface of the PEM. Route the power cable out through the right side, so that it fits through the
notch on the right side of the front bezel cover. (Figure 13)
62524
POWER
FAULT
ALARMS
CISCO
10000
FAIL
PERFORMANCE ROUTING ENGINE
CONSOLE
STATUS
ACO
CRITICAL
MINOR
MAJOR
ETHERNET
LINK
ACTIVITY
AUX
SLOT 0
SLOT 1
ALARMS
CISCO
10000
FAIL
PERFORMANCE ROUTING ENGINE
CONSOLE
STATUS
ACO
CRITICAL
MINOR
MAJOR
ETHERNET
LINK
ACTIVITY
AUX
SLOT 0
SLOT 1
POWER
FAULT