Datasheet

Configuring Voice
Configuring Voice Settings
136 Cisco SRP500 Series Services Ready Platforms Administration Guide (SRP520 Models)
6
Regional Page
Use the Regional page to localize your system with the appropriate regional
settings. The following sections appear on the Regional page.
Call Progress Tones
Distinctive Ring Patterns
Distinctive Call Waiting Tone Patterns
Distinctive Ring/CWT Pattern Names
Ring and Call Waiting Tone Spec
Control Timer Values (sec)
Vertical Service Activation Codes
Vertical Service Announcement Codes
Outbound Call Codec Selection Codes
Miscellaneous
Defining Ring and Cadence and Tone Scripts
To define ring and tone patterns, the SRP uses the concept of scripts. The
following defines how to create Cadence Scripts (CadScripts), Frequency Scripts
(FreqScripts) and Tone Scripts (ToneScripts).
CadScript
A mini-script of up to 127 characters that specifies the cadence parameters of a
signal.
Syntax: S
1
[;S
2
], where:
S
i
=D
i
(on
i
,1/off
i
,1[,on
i
,
2
/off
i
,
2
[,on
i,3
/off
i
,
3
[,on
i
,
4
/off
i
,
4
[,on
i
,
5
/off
i
,
5
,on
i
,
6
/off
i,6
]]]]]) and is
known as a section, on
i,j
and off
i,j
are the on/off duration in seconds of a segment
and i = 1 or 2, and j = 1 to 6. D
i
is the total duration of the section in seconds. All
durations can have up to three decimal places to provide 1 ms resolution. The
wildcard character “*” represents infinite duration. The segments within a section
are played in order and repeated until the total duration is played.
Example 1: 60(2/4)
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60 s
Number of Segments = 1