Regional
Cisco SPA232D Administration Guide 88
4
- Ring Frequency: 25
- Ring Voltage: 80Vc
Control Timer Values (sec)
Field Description
Ring Waveform Waveform for the ringing signal. Choices are Sinusoid or
Trapezoid.
Default setting: Sinusoid
Ring Frequency Frequency of the ringing signal. Valid values are 10–100
(Hz)
Default setting: 20
Ring Voltage Ringing voltage. Choices are 60–90 (V)
Default setting: 85
CWT Frequency Frequency script of the call waiting tone. All distinctive
CWTs are based on this tone.
Default setting: 440@-10
Synchronized Ring If this is set to yes, when the ATA is called, all lines ring at
the same time (similar to a regular PSTN line) After one line
answers, the others stop ringing.
Default setting: no
Field Description
Hook Flash Timer
Min
Minimum on-hook time before off-hook qualifies as hook
flash. Less than this the on-hook event is ignored. Range:
0.1–0.4 seconds.
Default setting: 0.1
Hook Flash Timer
Max
Maximum on-hook time before off-hook qualifies as hook
flash. More than this the on-hook event is treated as on
hook (no hook-flash event) Range: 0.4–1.6 seconds.
Default setting: 0.9
Callee On Hook
Delay
Phone must be on-hook for at this time in sec. before the
ATA will tear down the current inbound call. It does not
apply to outbound calls. Range: 0–255 seconds.
Default setting: 0