User guide

Using the Phone Web User Interface
Setting Voice Regional Parameters
Cisco Small Business SPA50X and SPA51X Series SPCP IP Phone User Guide 53
5
Tone S cript
A ToneScript is a mini-script that specifies the frequency, level, and cadence of a
call progress tone. It can include up to 127 characters.
Syntax: FreqScript;Z1[;Z2]
The section Zi is similar to the Si section in a CadScript except that each on/off
segment is followed by a frequency components parameter:
Zi = Di(oni,1/offi,1/fi,1[,oni,2/offi,2/fi,2 [,oni,3/offi,3/
fi,3 [,oni,4/offi,4/fi,4 [,oni,5/offi,5/fi,5 [,oni,6/offi,6/
fi,6]]]]])
where fi,j = n1[+n2]+n3[+n4[+n5[+n6]]]]] and 1 <nk<6 indicates
which of the frequency components in the FreqScript shall be used in that
segment. If more than one frequency component is used in a segment, the
components are summed together.
Holding Tone Informs the local caller that the far end has placed
the call on hold.
Defaults to 600@-19*(.1/.1/1,.1/.1/1,.1/9.5/1).
Conference Tone Played to all parties when a three-way conference
call is in progress.
Defaults to 350@-19;20(.1/.1/1,.1/9.7/1).
Secure Call Indication Tone Played when a call has been successfully
switched to secure mode. It should be played only
for a short while (less than 30 seconds) and at a
reduced level (less than -19 dBm) so it does not
interfere with the conversation.
Defaults to 397@-19,507@-19;15(0/2/0,.2/.1/1,.1/
2.1/2). (Before attempting to use Secure Call,
verify with your phone service provider that
Secure Call is available.)
Page Tone Specifies the tone transmitted when the paging
feature is enabled.
Defaults to 600@-16;.3(.05/0.05/1).
Alert Tone Played when an alert occurs.
Defaults to 600@-19;.2(.05/0.05/1).
Parameter Description