Specifications
7
Installing Cisco ONS 15454 SONET/SDH OPT-BST Cards
78-16594-02
Install the OPT-BST Card
Figure 4 Installing an ONS 15454 Card in the ANSI Shelf Assembly
Step 1 Plan your node installation or consult the site plan. As soon as you begin installing cards, ANS
determines what kind of site to set up based on the following parameters:
• Hub site—Two 32DMX-O and two 32MUX-O cards are provisioned but no AD-xC or AD-xB cards
are provisioned
• Terminal—One 32DMX-O and one 32MUX-O card are provisioned, and no AD-xC or AD-xB cards
are provisioned
• Line site—Only one OPT-PRE or OPT-BST is provisioned per line direction. (Up to two OPT-PRE
and/or two OPT-BST cards can be provisioned in the same shelf.)
• OADM site—At least 1 AD-xC or AD-xB is provisioned and no 32DMX-O or 32MUX-O cards are
provisioned
• Unknown—Provisioned cards do not follow any of the previously listed categories.
Step 2 Open the card latches/ejectors.
Step 3 Use the latches/ejectors to firmly slide the DWDM card along the guide rails until the card plugs into the
receptacle at the back of the slot.
Step 4 Install the card in any open east and west pair of slots. OPT-BST cards are often installed in Slots 1 and
17.
Step 5 Verify that the card is inserted correctly and close the latches/ejectors on the card.
FAN FAIL
CRIT
MAJ
MIN
39391
Guide rail
Ejector