System information

Managing Device Diagnostics
Te st in g C op p e r P o r ts
Cisco Small Business 300 Series Managed Switch Administration Guide 59
7
Link Status—Current link Up/Down status.
Pair—Cable wire pairs being tested.
Distance to Fault—Distance between the port and the location on the cable
where the fault was discovered.
StatusWire pair status. Red indicates fault and Green indicates status OK.
Cable length—Cable length in meters.
If the link is down, TDR Technology is used to test the GE and FE ports. Cable
length measurements are accurate to within 3 to 4 meters.
If the link is up, DSP Technology is used to test the GE ports. (FE ports are not
tested for length.) The values returned are:
- 1—Less than 50 meters
- 2—50 to 80 meters
- 3—80 to 110 meters
- 4—110 to 140 meters
- 5—More than 140 meters
Channel—Cable channel.
Polarity—Indicates if automatic polarity detection and correction has been
activated for the wire pair.
Pair Skew—Difference in delay between wire pairs.
STEP 5 Click Close to close the window.