User guide

3-11
Cisco H.323 Signaling Interface User Guide
OL-2156-04 Rev. A1
Chapter 3 Provisioning the Cisco HSI
H.323 Stack Configuration
Note Immediate and next call update types are dynamic system data.
Note The RAS parameter overlappedSending is not available here because it has been combined with the
Q.931 overlappedSending parameter. If you set the Q.931 overlappedSending parameter, you also set the
the RAS overlappedSending parameter.
Note The asterisk (*) after a parameter name in the first column of Table 3-8 denotes a mandatory RADVision
parameter with an inbuilt default value that will be used if the value is not set in provisioning.
Table 3-8 RAS Parameters
Parameter Name Description Type Example Update Type
manualRAS If this parameter is present,
the stack does not perform
automatic RAS procedures
(it waits to be driven by the
application).
NULL Start
responseTimeOut* The time (in seconds) that
the stack waits until it
notifies the application that
the called party has failed to
respond to a transaction.
INTEGER(1, 200) 10 Immediate
maxFail* Maximum number of retry
gatekeeper registration
attempts.
INTEGER(1, 200) 3 Immediate
allowCallsWhenNonReg If this parameter is present, it
allows calls to proceed even
if gatekeeper registration has
not been done for the
PGW 2200.
NULL Not present Immediate
manualRegistration If this parameter is present,
the stack does not perform
automatic gatekeeper
registration procedures (it
waits to be driven by the
application).
NULL Not present Stop/Start
timeToLive The maximum time (in
seconds) the registration of
the PGW 2200 with a
gatekeeper remains valid.
The stack reregisters
periodically.
INTEGER(1, 65535) 400 Immediate