User guide

3-7
Cisco H.323 Signaling Interface User Guide
OL-2156-04 Rev. A1
Chapter 3 Provisioning the Cisco HSI
Cisco HSI Configuration
OVLDLEVEL2FILTER Indicates what call types should be gapped if an overload level 2
condition occurs (see OVLDLEVEL1FILTER).
Normal
OVLDLEVEL2THRESHLOWER
CALLS
Determines the number of active calls below which the application
load must fall in order for the overload level 2 condition to be
removed.
2000
OVLDLEVEL2THRESHUPPER
CALLS
Determines how many simultaneous active calls trigger an overload
level 2 condition.
2200
OVLDLEVEL2THRESHLOWER
CPU
Determines the level of CPU utilization below which the application
must fall in order for the overload level 2 condition to be removed.
70
OVLDLEVEL2THRESHUPPER
CPU
Determines the level of CPU utilization that triggers an overload
level 2 condition.
80
OVLDLEVEL3PERCENT Indicates what percentage of calls should be rejected when an
overload condition occurs. The parameter is used in conjunction with
the OVLDLEVEL3FILTER parameter. This is the highest level of
overload and must be greater than or equal to the provisioned values
for OVLDLEVEL1PERCENT and OVLDLEVEL2PERCENT.
Note If this value is set to zero, no overload treatment occurs (by
definition, the level 1 and level 2 values must also be zero).
90
OVLDLEVEL3FILTER Indicates what call types should be gapped if an overload level 3
condition occurs (see OVLDLEVEL1FILTER).
Normal
OVLDLEVEL3THRESHLOWER
CALLS
Determines the number of active calls below which the application
load must fall in order for the overload level 3 condition to be
removed.
2300
OVLDLEVEL3THRESHUPPER
CALLS
Determines how many simultaneous active calls trigger an overload
level 3 condition.
2400
OVLDLEVEL3THRESHLOWER
CPU
Determines the level of CPU utilization below which the application
must fall in order for the overload level 3 condition to be removed.
85
OVLDLEVEL3THRESHUPPER
CPU
Determines the level of CPU utilization that triggers an overload
level 3 condition.
95
CIAGENTSCANPERIOD Specifies the frequency with which the CIagent polls the CPU
utilization.
ALARMDEBOUNCETIME Specifies the length of time that an alarm condition must persist
before being reported, and any associated action taken.
0
CALLREFERENCEUSAGE Determines which call reference identity is passed on to the
PGW 2200 (call reference field or Conference ID).
Table 3-4 Dynamic System Data Parameters (continued)
Parameter Description Default