Datasheet

Data Sheet
© 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 5 of 6
Features Descriptions
Environmental specifications Operating temperature: 41 to 104°F (5 to 40°C)
Storage temperature: –38 to 15F (–40 to 7C)
Operating humidity: 5 to 85% relative humidity
Storage humidity: 5 to 95% relative humidity
Compliance and agency
approvals
Safety
UL 60950
CSA 22.2-No.60950
EN60950
IEC 60950 CB Scheme
ACA TS001
AS/NZS 3260
EN60825\IEC60825 laser safety (SR, IR-Class 1) (VSR-Class 1M)1
21CFR1040 -FDA Code of Federal Regulations (USA) laser safety (SR, IR-Class 1)
(VSR-Class 1M)1
EMC
FCC Part 15 (CFR 47)
ICES 003
EN55022
CISPR 22
AS/NZS CISPR22
VCCI
EN55024
EN50082-1
EN61000-6-1
EN61000-3-2
EN61000-3-3
Network Equipment Building Standards (NEBS)
This product is designed to meet the following requirements (official qualification may be in
progress):
SR-3580 – NEBS: Criteria levels (Level 3 compliant)
GR-63-CORE – NEBS: Physical protection
GR-1089-CORE – NEBS: EMC and safety
Table 2. Optical Specifications for the Cisco 2-Port Channelized OC-12 SPA
SFP Optics Maximum Distance
Multimode (MM) Up to 0.25 mi (500m)
Single-mode (SM) Up to 1.2 mi (2 km)
SM intermediate reach (IR-1) Up to 9 mi (15 km)
SM long reach (LR-1) Up to 25 mi (40 km)
SM extended reach (LR-2) Up to 50 mi (80 km)
Power and Environmental Requirements
When installed in Cisco routers, these SPAs do not change the power or environmental
requirements and standards of the router platform itself. Refer to the platform-specific data sheets