Specifications

Table Of Contents
2-67
Cisco SCE 2000 and SCE 1000 CLI Command Reference
OL-26797-03
Chapter 2 CLI Command Reference
clock timezone
clock timezone
Sets the time zone. Use the no version of this command to remove current time zone setting. The purpose
of setting the time zone is so that the system can correctly interpret time stamps data coming from
systems located in other time zones.
clock timezone zone hours [minutes]
no clock timezone
Syntax Description
Command Default UTC (hours = 0)
Command Modes Global configuration
Command History This table includes the following release-specific history entries:
Usage Guidelines Authorization: admin
Examples The following example sets the time zone to Pacific Standard Time with an offset of 10 hours behind
UTC.
SCE>enable 10
Password:<cisco>
SCE#config
SCE(config)#clock timezone PST –10
SCE(config)#
Related Commands
zone The name of the time zone to be displayed.
hours The hours offset from UTC. This must be an integer in the range –23 to 23.
minutes The minutes offset from UTC. This must be an integer in the range of 0 to
59. Use this parameter to specify an additional offset in minutes when the
offset is not measured in whole hours.
Release Modification
2.5.7 This command was introduced.
Command Description
calendar set Sets the system calendar.
clock set Manually sets the system clock.
show calendar Displays the time maintained by the real-time system calendar clock.