Chapter 4 Installation and Startup
Connecting the Local Console
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 4-25
The above SCE 1000 port parameters are fixed and are not configurable.
To set up the local console:
Step 1 Plug the enclosed RS-232 serial cable into the CON port on the front panel of the SCE
1000.
Make sure that you push on the RJ-45 connector (attached to the RS-232 serial cable)
until you hear a “click”, which indicates that the connector is fully inserted and secured
in the receptacle. Gently pull on the plug to confirm whether the plug is locked into the
socket.
Step 2 Connect the other end of the serial cable (with an attached DB-9 connector) to the
VT100 compatible local (serial) terminal.
Step 3 Make sure the local terminal is configured as a VT-100 terminal, according to the fixed
SCE 1000 CON port parameters.
Step 4 Press Enter several times until the setup configuration dialog is entered.
--- System Configuration Dialog ---
At any point you may enter a question mark ‘?’ followed by ‘Enter’ for help.
Use ctrl-C to abort configuration dialog at any prompt.
Use ctrl-Z to jump to the end of the configuration dialog at any prompt.
Default settings are in square brackets ‘[]’.
Would you like to continue with the System Configuration Dialog? [yes/no]: y
Step 5 Type y and press Enter.
The system configuration dialog begins.