User guide

Appendix B
Chassis Group: chassisGrp (pcubeSEObjs 2)
SCE 1000 2xGBE Release 2.0.10 User Guide
B-18 OL-7117-02
Chassis Group: chassisGrp (pcubeSEObjs 2)
The Chassis group defines and identifies the chassis, as well as environmental alarms related to
the chassis.
ChassisSysType (chassisGrp 1)
The chassis system type.
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (SE1000): SE1000 platform
3 (SE100): SE100 platform
4 (SE2000): SE2000 platform
}
chassisPowerSupplyAlarm (chassisGrp 2)
Indicates whether the power supply to the chassis is normal. If the alarm is ‘on’, it means that one
or more of the power supplies is not functional
Access RO
S
YNTAX
INTEGER {
1 (other): none of the following
2 (off): the power supply to the chassis is normal
3 (on): the power supply to the chassis is not normal, and probably one or more of the power
supplies is not functional.
}