User guide

Appendix A
Privileged Exec Mode Commands
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 A-61
[no] blink slot slot-number
Blinks a slot LED for visual identification. Use the [no]form of this command to stop the slot
blinking.
Default Not blinking
Authorization admin
Mode Privileged EXEC
P
ARAMETERS
slot-number The number of the identified slot. Enter a value of 0.
E
XAMPLE:
The following example configures the SCE 1000 to stop blinking.
SCE 1000#no blink slot 0
SCE 1000#
calendar set hh:mm:ss day month year
Sets the system calendar. The calendar is a system clock that continues functioning even when the
system shuts down.
Authorization admin
Mode Privileged EXEC
P
ARAMETERS
hh:mm:ss Current local time in hours in 24-hour format, minutes and seconds
(HH:MM:SS).
day Current day (date) in the month.
month Current month (by three-letter abbreviated name).
year Current year using a 4-digit number.
U
SAGE GUIDELINES
Always coordinate between the calendar and clock by using the clock read-calendar
command after setting the calendar.
For further information on setting the clock, see Setting the Clock (on page 6-12).
E
XAMPLE:
The following example sets the calendar to 20 minutes past 10 AM, October 13, 2001,
synchronizes the real-time clock to the calendar time, and displays the result.
SCE 1000#calendar set 10:20:00 13 oct 2001
SCE 1000#clock read-calendar
SCE 1000#show calendar
10:20:03 UTC THU October 13 2001
SCE 1000#show clock
10:20:05 UTC THU October 13 2001
SCE 1000#