Chapter 4 Installation and Startup
Connecting the FE Management Port
SCE 1000 2xGBE Release 2.0.10 User Guide
OL-7117-02 4-47
To cable the management port:
Step 1 Take the Ethernet LAN cable (with attached RJ-45 connector) and plug it into the Mng
port on the front panel of the SCE 1000, as shown in the figure below.
Figure 4-18: Cabling the Management Port
Step 2 Connect the other end of the Ethernet LAN cable into your management network.
Make sure that you push on the RJ-45 connector (attached to the Ethernet cable) until
you hear a click, which indicates that the connector is fully inserted and secured in the
receptacle. Gently pull on the plug to confirm whether the plug is locked into the socket.
If the Link LED on the SCE 1000 management port does not light, try removing the
network cable plug and reinserting it firmly into the module socket. To disconnect the
plug from the socket, press down on the raised portion on top of the plug, releasing the
latch. You should hear an audible click indicating the latch has released. Carefully pull
the plug out of the socket.
If the management port Link LED on the SCE 1000 still does not light, verify that the
cable is connected correctly to the appropriate network element on its second end.
Step 3 After you connect the FE cable to the Mng port and to your network, check the FE Mng
port LEDS.
There are 3 FE LEDs: Link, 10/100, and Active (see, in Front Panel, the figure SCE
1000 Front Panel and the table SCE 1000 LED Groups.
At this point, check that the Link LED is green. The 10/100 LED is green depending on
the Ethernet network settings. Green indicates that the 10/100 Led is 100 Mbps., and
‘Off indicates 10 Mbps.
Step 4 Test connectivity. From the host that you intend to use for remote management, ping to
the SCE 1000 by typing ping and the SCE 1000 IP address, and pressing Enter (see the
example, below).