Datasheet

35
Release Notes for Catalyst 4500 Series Software Release 7.x
OL-1983-28
Open and Resolved Caveats in Software Release 7.6(1)
A Catalyst 4006 switch with port channels enabled on the supervisor engine trunk can have a
communication failure between interVLANs.
Workaround: There is no workaround. This problem is resolved in software release 7.6(2).
(CSCdz66547)
When you enter the show cam dynamic vlanid command, the message “Unable to contact module x”
displays and VMPS does not work.
Workaround: There is no workaround. This problem is resolved in software release 7.6(2).
(CSCea69221)
Dynamic VLANs are not always updated on the switch when the incoming SA changes.
Workaround: There is no workaround. This problem is resolved in software release 7.6(2).
(CSCea50001)
If you enable port security and MAC address learning on a switch, when the port sees a MAC address
that contains all zeros, the port is disabled and there is no “Last-Src-Addr.
Workaround: Reenable the port. This problem is resolved in software release 7.6(2).
(CSCea89001)
Disabling 802.1X does not work for single authentication and multiple host modes.
Workaround: No workaround is available. You can bring the port back to a normal state by using
the clear config all command followed by resetting the switch. This problem is resolved in software
release 7.6(2). (CSCin41724)
There is a memory leak that increases the memory held by the console in 16 byte increments. This
memory leak presents itself in one of two ways:
When you configure a community or isolated VLAN to a primary VLAN using the SNMP CLI.
Free memory reduces constantly and the memory held by the SptTimer and DTP_Rx process.
You can use the show proc mem command to view the memory held by processes and verify if you
have a memory leak.
Workaround: There is no workaround. (CSCea91118)
Open and Resolved Caveats in Software Release 7.6(1)
These sections describe the open and resolved caveats in supervisor engine software release 7.6(1):
Open Caveats in Software Release 7.6(1), page 35
Resolved Caveats in Software Release 7.6(1), page 36
Open Caveats in Software Release 7.6(1)
These caveats are open in software release 7.6(1):
A Catalyst 4500 series switch running in the access layer may display loop guard-inconsistent
messages if a topology change occurs in corresponding designated switches that have a high number
of spanning tree instances. The switch recovers on its own and does not cause a network outage.
Workaround: There is no workaround. (CSCdz65842)