Specifications

24 Installing the RSP7000 Upgrade Kit in the Cisco 7000 Series Routers
Checking the Installation
The show environment table command displays the temperature and voltage thresholds for each of
the three RSP7000 temperature sensors, for each monitored status level: low critical, low warning,
high warning, and high critical. The slots in which the RSP7000 can be installed are indicated in
parentheses (2 and 3). Also listed are the shutdown thresholds for the processor boards and power
supplies. An example of the show env table command follows for both the Cisco 7000 and
Cisco 7010:
RSP7000#sho env table
Sample Point LowCritical LowWarning HighWarning
HighCritical
CI(6) Inlet 44C/111F 50C/122F
CI(6) Hotpoint 54C/129F 60C/140F
CI(6) Exhaust
+12 Voltage 10.90 11.61 12.82 13.38
+5 Voltage 4.61 4.94 5.46 5.70
-12 Voltage -10.15 -10.76 -13.25 -13.86
+24 Voltage 20.38 21.51 26.42 27.65
2.5 Reference 2.43 2.51
Shutdown power supplies at 70C/158F
RSP7010#sho env table
Sample Point LowCritical LowWarning HighWarning
HighCritical
CI(4) Inlet 44C/111F 50C/122F
CI(4) Hotpoint 54C/129F 60C/140F
CI(4) Exhaust
+12 Voltage 10.90 11.61 12.82 13.38
+5 Voltage 4.61 4.94 5.46 5.70
-12 Voltage -10.15 -10.76 -13.25 -13.86
+24 Voltage 20.38 21.51 26.42 27.65
2.5 Reference 2.43 2.51
Shutdown power supplies at 70C/158F
The show environment all command displays an extended report that includes the arbiter type,
backplane type, power supply type (AC or DC), wattage and status, the number and type of
intermittent power failures (if any) since the system was last powered on, and the currently measured
values at the RSP7000 temperature sensors and the power supply voltages. An example of the
show env all command follows for both the Cisco 7000 and Cisco 7010:
RSP7000#sho env all
Arbiter type 1, backplane type 70x0 (id 5)
Power supply #1 is 700W (id 2), power supply #2 is removed (id 3)
Active fault conditions: none
Active trip points: none
0123456
Dbus slots: X X
card inlet hotpoint exhaust
CI(6) 21C/69F 30C/86F 22C/71F
Shutdown temperature source is 'hotpoint' on CI(6),
requested CI(6)
+12V measured at 12.12
+5V measured at 5.13
-12V measured at -11.84
+24V measured at 24.06
+2.5 reference is 2.49