Specifications
3-9
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
Quickstart Provisioning Procedures
PNNI Virtual Trunk Configuration Quickstart
Virtual trunks are introduced and explained in the Cisco MGX 8800/8900 Series Configuration Guide,
Release 5.2.
Command Comments
Step 1
Follow the steps in the “MPLS and
PNNI Trunk Configuration
Quickstart” section on page 3-3.
Configure the trunks that link the switches through which the ATM
end stations connect. Be sure to add the appropriate controller
(either PNNI or MPLS) on each switch and select that controller
when partitioning trunks.
Step 2
dsppnni-reachable-addr
network
On the PXM, verify connectivity between the node pairs that will
host SVCs.
See the “Verifying PNNI Communications” section on page 4-52.
Step 3
Follow the steps in the “MPLS and
PNNI UNI Port Configuration
Quickstart” section on page 3-5.
Configure UNI ports for the ATM end stations at each end of the
SVC, and assign either static or dynamic addressing to each line.
Be sure to add the appropriate controller (either PNNI or MPLS)
on each switch and select that controller when partitioning trunks.
Step 4
cc Change to the AXSM card.
Step 5
addcon
Related commands:
dspchans
dspchan
If you are configuring a double-ended SPVC, configure the slave
side of the SPVC or SPVP.
If the slave side of the connection is on the AXSM card, see the
“Configuring the Slave Side of SPVCs and SPVPs” section on
page 3-55.
If the slave side of the connection is on a non- AXSM card, refer
to the documentation for that card.
Note If you are configuring a single-ended SPVC or SPVP, you
do not need to configure the slave end of the SPVC or
SPVP.
Step 6
dspcon Verify the configuration for the connection you added inStep 5
Step 5.
Step 7
username
<password>
or
cc
If you are configuring an SPVC or SPVP between:
• The AXSM and a remote card, change to the remote card.
• Two ports on the current AXSM card, you can skip this step
and proceed to Step 8.
Step 8
addcon
Related commands:
dspcon
dspcons
Add and configure the master side of an SPVC or SPVP on the
remote card.
If the master side of the connection is on:
• The AXSM card, see the “Configuring SPVCs and SPVPs”
section on page 3-54.
• A non- AXSM card, refer to the documentation for that card.
Step 9
dsppncons This optional step displays the SVC connections that are
operating. Enter this command on the active PXM.