Specifications
3-5
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
Quickstart Provisioning Procedures
MPLS and PNNI UNI Port Configuration Quickstart
ATM User-to-Network Interface (UNI) ports connect the switch to ATM end devices, which serve as the
boundary between the ATM network and other communications paths or networks. Typical end devices
include ATM routers and multiservice concentrators. UNI signaling is used between the end system
(CPE) and the PNNI network for requesting calls.
The quickstart procedure in this section provides a summary of the tasks required to configure UNI ports
on AXSM cards. This procedure is provided as an overview and as a quick reference for those who have
previously configured UNI ports.
Step 10
cc
dsppnni-link
dsppnni-neighbor
When both ends of the link are configured, change to the active
PXM card and verify the PNNI communications between the two
ends of the connection. In the dsppnni-link report, there should be
an entry for the port for which you are verifying communications.
The Hello state reported should be twoWayInside, and the Remote
node ID should display the remote node ATM address after the
second colon.
See the “Verifying PNNI Communications” section on page 4-52.
Step 11
cc Change back to the AXSM card.
Step 12
upilmi
cnfilmi
Related commands:
dspports
dspilmis
This step is optional. Configure and start ILMI on trunks where
you want to support Cisco WAN Manager (CWM) or use ILMI
features.
See the “Configuring ILMI on a Port” section on page 3-47.
Command Comments
Command Comments
Step 1
username
<password>
Start a configuration session.
To perform all the steps in this quickstart procedure, you must log
in as a user with GROUP1 privileges or higher.
Step 2
cc Change to the AXSM card.
Step 3
Bring up AXSM lines as described in the “Preparing AXSM Lines
for Communication” section on page 2-1