Specifications

5-445
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 5
startimalnktst
startimalnktst
Start IMA Link Test—AXSM-32-T1E1-E
Starts an IMA link connectivity test on a specified link in a specified IMA group. You can check that an
IMA link connection is valid by sending a test pattern to the link. The test pattern is a number in the
range of 0–254. If the test pattern number is the same when it arrives at the receive endpoint of the link,
then the link is valid. If the test pattern number is different or does not arrive at all, then the link is
invalid. You can run only one test at a time.
Syntax
startimalnktst <group> <link> <test Pattern>
Syntax Description
Related Commands
stopimalnktst, cnfimalnktst
Attributes
Example
Start IMA link test on bay 1, group 1, link 2, using test pattern 1:
MGX8850.2.AXSME.a> startimalnktst 1.1 2 1
group The bay number (1–2) and the IMA group number (1–16) in the format bay.group.
For example: 1.16
link The bay number (1–2) and the IMA link number (1–16) in the format bay.link. For
example: 1.16
test Pattern The test pattern number. Range: 0–254.
If no value is entered, -1 is the default, which causes the program to select a pattern.
Log: yes State: active Privilege: GROUP1