Specifications

5-137
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 5
cnfln
5
cnfln
Configure Line—AXSM, AXSM-E, AXSM-XG, AXSM-32-T1E1-E
Configures a line on the current service module. Use cnfln after you have activated the line using upln.
Note You cannot configure a line that currently has any configured virtual interfaces on it. To configure a line
on an SRM, see the cnfln description that appears before the current description.
Note The syntax varies according to the line type, so each line type has a description.
Syntax (SONET)
cnfln -sonet <bay.line> -slt <LineType> -clk <clockSource> -description <circuitIdentifier>
Syntax Description (SONET)
Syntax (DS3)
cnfln -ds3 <bay.line> -len <LineLength> -clk <clockSource> -id <circuitIdentifier>
-sonet Enter the keyword (-sonet) followed by the bay.line number. For example:
-sonet 1.2
Ranges:
bay: 1–2
line: 1–8
-slt Enter the keyword (-slt) followed by the LineType identifier. Identifiers:
1 = SONET
2 = SDH
-clk Enter the keyword (-clk) followed by the clockSource identifier. Identifiers:
1 = loopTiming
2 = localTiming
-description The circuitIdentifier is a text string with up to 64 characters that uniquely identifies
the line.