Specifications

4-27
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 4 AXSM Card Management
Managing Port SCTs
| 8 | 452105 | 452105 | 429499 | 452105 | 429499 |
| 9 | 452105 | 452105 | 429499 | 452105 | 429499 |
| 10 | 452105 | 27126 | 429499 | 452105 | 429499 |
| 11 | 22605 | 22605 | 18084 | 18084 | 13563 |
| 12 | 45210 | 45210 | 36168 | 36168 | 27126 |
| 13 | 226052 | 226052 | 180841 | 180841 | 135631 |
| 14 | 452105 | 452105 | 361684 | 361684 | 271263 |
| 15 | 452105 | 452105 | 361684 | 361684 | 271263 |
Type <CR> to continue, Q<CR> to stop:
| 16 | 452105 | 22605 | 316473 | 361684 | 361684 |
+------------------------------------------------------------+
+-----------------------------------------------------------+
| Service Class Template [ 5] : COSB Threshold Parameters |
+-----------------------------------------------------------+
|COSB| MAX_CELL | REDHI_01 | REDHI_1 | REDLO_01 | REDLO_1 |
| |THR(Cells)|(in Cells)|(in Cells)|(in Cells)|(in Cells)|
+-----------------------------------------------------------+
| 1 | 22605 | 16953 | 15823 | 14693 | 12432 |
| 2 | 22605 | 16953 | 15823 | 14693 | 12432 |
| 3 | 22605 | 16953 | 15823 | 14693 | 12432 |
| 4 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 5 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 6 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 7 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 8 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 9 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 10 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 11 | 22605 | 0 | 0 | 0 | 0 |
| 12 | 45210 | 33907 | 31647 | 29386 | 24865 |
| 13 | 226052 | 169539 | 158236 | 146933 | 124328 |
| 14 | 452105 | 339078 | 316473 | 293868 | 248657 |
Type <CR> to continue, Q<CR> to stop:
| 15 | 452105 | 339078 | 316473 | 293868 | 248657 |
| 16 | 452105 | 339078 | 316473 | 293868 | 248657 |
+-----------------------------------------------------------+
Table 4-9 describes the SCT COSB parameters shown in the example.
Table 4-9 SCT COSB Threshold Parameter Descriptions
Label Range and Units Description
COSB The service type (for example, CBR, VBR,
ABR) to which the parameters (for example,
EFCI, CLP_HI, EPD0) in this table apply.
MAX_THR (cells)
or
MAX_CELL THRESH
0–5000000
microseconds
The maximum threshold, in microseconds,
beyond which all CLP (0+1) cells must be
dropped.
Note On the AXSM/A and AXSM/B cards,
this parameter is called
“MAX_CELL THRESH.” On the
AXSM-XG and AXSM-E cards, this
parameter is called “MAX_THR
(cells).”