Specifications

3-56
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
General AXSM Configuration Procedures
Note You can configure additional ABR parameters on the AXSM-E and AXSM-XG cards with the cnfabr
command. For more information, refer to the Cisco MGX 8800/8900 Series Command Reference,
Release 5.2. Note that the AXSM/A and AXSM/B cards do not support the cnfabr command.
The following command example defines a port as the slave side of an SPVC. Note the slave id shown
in the command response.
MGX8850.1.AXSM.a > addcon 3 101 101 1 2
slave endpoint added successfully
slave endpoint id : 4700918100000000001A531C2A00000101180300.101.101
Step 4 Write down the NSAP address the switch displays when the addcon command is complete. You will
need this to configure the master side of the SPVC.
Tip When you set up the master side of the connection, you will have to enter the slave ATM address reported
by the addcon command. If you maintain the current session or use the session Copy command to copy
the ATM address now, you can use the session Paste command to complete the addcon command on the
switch that hosts the master side of the connection.
Step 5 Verify the slave-side SPVC addition by entering the following command:
MGX8850.1.AXSM.a > dspcons
The switch displays a report similar to the following:
MGX8850.1.AXSM.a > dspcons
record Identifier Type SrvcType M/S Upld Admn Alarm
------ ---------- ---- -------- --- ---- ---- -----
0 03 0101 00101 VCC cbr1 S 02022a26 UP Condn
Configuring the Master Side of SPVCs and SPVPs
To configure the master side of an SPVC, use the following procedure.
Step 1 Establish a configuration session using a user name with GROUP1 privileges or higher.
Tip During this procedure, you will have to enter the ATM address for the slave end of the connection. If you
establish this session from the same workstation you used to create the slave connection, you can use the
Copy and Paste commands to avoid data entry errors.
Step 2 Enter the cc command to select the AXSM card that hosts the master side of the SPVC:
MGX8850.7.PXM.a > cc <slotnumber>
Step 3 Define the master side of the SPVC by entering the following command:
M8950_DC.5.AXSM.a > addcon <
ifNum
> <
vpi
> <
vci
> <
serviceType
> <
mastership
>
[-slave
atmAddr
.
vpi
.
vci
] [-lpcr <
cellrate
>] [-rpcr <
cellrate
>] [-lscr <
cellrate
>]
[-rscr <
cellrate
>] [-lmbs <
cells
>] [-rmbs <
cells
>] [-cdvt <
time
>]
[-lcdv <
time
>] [-rcdv <
time
>] [-lctd <
time
>] [-rctd <
time
>]
[-cc <1|0>] [-stat <1|0>] [-frame <1|0>] [-mc <
maxCost
>] [-lputil <local>]
[-rputil <remote>] [-slavepersflag <slavepers>] [-rtngprio <routingPriority>]