Specifications
3-46
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
General AXSM Configuration Procedures
Replace <portid> using the format slot:bay.line:ifNum.
Note This step is required to enable testing with the tstdelay command.
Step 7 Enter the uppnport command to bring up the port you just configured:
MGX8850.7.PXM.a > uppnport <
portid
>
Replace <portid> using the format slot:bay.line:ifNum.
Step 8 To verify the status of the port, enter the dsppnports command.
Step 9 To display the configuration of the PNNI port, enter the dsppnport command:
MGX8850.7.PXM.a > dsppnport <
portid
>
Replace <portid> using the format slot:bay.line:ifNum. The following example shows the report for this
command.
M8850.7.PXM.a > dsppnport 5:1.1:11
Port: 5:1.1:11 Logical ID: 17111051
IF status: up Admin Status: up
UCSM: enable SVC Routing Pri: 8
Auto-config: enable Addrs-reg: enable
IF-side: network IF-type: nni
UniType: private Version: pnni10
PassAlongCapab: n/a
Input filter: 0 Output filter: 0
minSvccVpi: 11 maxSvccVpi: 4095
minSvccVci: 35 maxSvccVci: 65535
minSvpcVpi: 11 maxSvpcVpi: 4095
P2P Details:
(P=Configured Persistent Pep, NP=Non-Persistent Pep, Act=Active)
#Spvc-P: #Spvc-NP: #SpvcAct: #Spvp-P: #Spvp-NP: #SpvpAct:
0 0 0 0 0 0
#Svcc: #Svpc: #Ctrl: Total:
0 0 0 0
P2MP Details:
(P=Persistent, NP=Non-Persistent, Pa = Party, Act=Active)
Type #Root: #Leaf: #Party:
svcc: 0 0 0
svpc: 0 0 0
#Spvc-P: #Spvc-NP: #SpvcAct: #Spvp-P: #Spvp-NP: #SpvpAct:
0 0 0 0 0 0
#SpvcPa-P:#SpvcPaAct:#SpvpPa-P: #SpvpPaAct:
0 0 0 0
Assigning Static ATM Addresses to Destination Ports
When a CPE does not support ILMI, the switch cannot automatically determine the CPE address. To
enable communications with the CPE, you must assign a static ATM address to the port leading to the
CPE. The static address must match the address used by the CPE.