Specifications

3-32
Cisco ATM Services (AXSM) Configuration Guide and Command Reference for MGX Switches
Release 5.2, Part Number OL-6484-01 Rev. C0, September 2005
Chapter 3 Provisioning ATM Services
General AXSM Configuration Procedures
Table 3-3 lists the parameters for configuring resource partitions.
Table 3-3 cnfpart Command Parameters
Parameter Description
-if Logical interface (port) number. The ranges are:
AXSM: 1–60
AXSM-E: 1–32
AXSM-XG: 1–126
-id The partition ID number. The ranges are as follows:
AXSM: 1–5
AXSM-E: 1–20
AXSM-XG: 1–20
-emin Specifies the guaranteed percentage of egress bandwidth. Each unit of egrMinBw is
0.00001 of the total bandwidth on the port. (An egrMinBw of 1000000 = 100%.) This
approach provides a high level of granularity.
-emax Specifies the maximum percentage of the bandwidth. Each unit of egrMaxBw is
0.00001 of the total bandwidth available to the port. (An egrMaxBw of 1000000 =
100%.) The resulting bandwidth must be at least 50 cps.
-imin Specifies the guaranteed percentage of the ingress bandwidth. Each unit of ingMinBw
is 0.00001 of the total bandwidth available to the port. For example, an ingMinBw of
1000000 = 100%.
-imax Specifies the maximum percentage of the ingress bandwidth. Each increment of
ingMaxBw is 0.00001 of the total bandwidth on the port. For example, an ingMaxBw
of 1000000 = 100%. Note that the maximum ingress bandwidth must be at least 50
cps.
-vpmin Specifies the minimum VPI. For NNI, the range is 0–4095. For UNI, the range is
0–255.
Note On a virtual trunk, the min_vpi and max_vpi must be the same.
-vpmax Specifies the maximum VPI in the range 0–4095 for an NNI. For a UNI, the range is
0–255. The maxvpi cannot be less than the minvpi.
Note On a virtual trunk, the min_vpi and max_vpi must be the same.
-vcmin Minimum VCI range: 0–2000 (OC-48 only) or 1–65535
-vcmax Maximum VCI: range: 0–2000 (OC-48 only) or 1–65535
-mincon Specifies the guaranteed number of connections. The range is between 0 and the
maximum number of connections in the port group. See dspcd for information about
port groups.
Note On UNI ports, 1% of the <minConns> value is reserved for signaling.
-maxcon Specifies the maximum number of connections. The range is between 10 and the
maximum number of connections in the port group. See dspcd port group information.
maxConns cannot be less than minConns.