SpecSheet Cisco UCS C460 M2 High-Performance RackMount Server Overview The Cisco UCS C460 M2 High-Performance Rack-Mount Server (Figure 1) is a four-rack-unit (4RU) server ® ® supporting the Intel Xeon processor E7-4800 product family, up to 1 terabyte (TB) of double-data-rate 3 (DDR3) memory in 64 slots, and 12 small form factor (SFF), hot-pluggable SAS and SATA disk drives.
Detailed Views Figure 2. Front View of the Cisco UCS C460 M2 Server Figure 3. Detailed View of Front Panels on the Cisco UCS C460 M2 Server Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes PCIe Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Figure 4. Rear View of the Cisco UCS C460 M2 Server Figure 5. Detailed View of the I/O Riser Module on the Rear of the Cisco UCS C460 M2 Server Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes PCIe Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Base Unit Features Table 1.
Configuring the Cisco UCS C460 M2 Server UCS C460 M2 base server. (required) STEP 1: UCSC-BASE-M2-C460 Select the CPU type. Select two or four CPUs from this list: ● 2.4 GHz Xeon E7-4870 130W 10C CPU/30MB cache UCS-CPU-E74870 ● 2.26 GHz Xeon E7-4860 130W 10C CPU/24MB cache UCS-CPU-E74860 ● 2.0 GHz Xeon E7-4850 130W 10C CPU/30MB cache UCS-CPU-E74850 ● 2.13 GHz Xeon E7-4830 105W 8C CPU/24MB cache UCS-CPU-E74830 ● 1.86 GHz Xeon E7-4807 95W 6C CPU/18MB cache UCS-CPU-E74807 ● 2.
STEP 2: Select the memory type.
● LSI 6G MegaRAID 9280-4i4e PCIe Card UCSC-C-4I4E ◦ Takes up one of five available PCIe slots ◦ Supports up to sixteen SAS and/or SATA drives ◦ Supports external JBOD expansion ◦ Battery Back-Up Option Available ● Battery Backup Option STEP 4: RC460-LBBU Select the 2.5-inch HDD drive type. Select a minimum of zero and a maximum of 12 drives from this list: ● 500 GB SATA 7.2k RPM SFF HDD/hot plug/C-Series drive sled R2XX-D500GCSATA ● 1 TB SATA 7.
STEP 5: Select a factory-configured RAID setup. Most customers prefer to configure their own RAID setup. If you would prefer that Cisco to configure the RAID, choose one of the following options: ● RAID 0 (Striping) R2XX-RAID0 Requires a minimum of one hard drive. ● RAID 1 (Mirroring) R2XX-RAID1 Requires exactly two hard drives with same size, speed and capacity. ● RAID 5 R2XX-RAID5 Requires a minimum of three HDDs, all with identical speed and capacity.
STEP 6: Select option cards. Select option cards from the following list. You can select a maximum of 10 PCIe cards. ● Cisco UCS P81E Virtual Interface Card/Dual port 10Gbps N2XX-ACPCI01 (Max.
STEP 8: Select the power cords. (optional) You can select a maximum of two power cables from this list: ● N5000 AC Power Cable, 6A, 250V, North America, 2.5m CAB-N5K6A-NA ● N5000 AC Power Cable, 13A, 250V, North America, 2.5m CAB-AC-250V/13A ● N5000 AC Power Cable, 6A, 250V, Power Strip Type CAB-C13-C14-JMPR ● N5000 AC Power Cable, 10A, 250V, Argentina, 2.5m SFS-250V-10A-AR ● N5000 AC Power Cable, 10A, 250V, Australia, 2.5m CAB-9K10A-AU ● N5000 AC Power Cable, 10A, 250V, China, 2.
STEP 10: Order the internal Flash USB device. (optional) You can order a maximum of two Flash USB devices. ● 2-GB internal Flash USB device STEP 11: RC460-EUSB Select the operating system. (optional) Various operating system options are available.
RHEL Add-Ons ● High-Availability/2 Socket/1Yr Svcs Required RHEL-HA-2S-1A ● High-Availability/2 Socket/3Yr Svcs Required RHEL-HA-2S-3A ● High-Availability/4 Socket/1Yr Svcs Required RHEL-HA-4S-1A ● High-Availability/4 Socket/3Yr Svcs Required RHEL-HA-4S-3A ● Resilient Storage With Ha /2 Socket/1 Yr Svcs Required RHEL-RS-2S-1A ● Resilient Storage With Ha /2 Socket/3 Yr Svcs Required RHEL-RS-2S-3A ● Resilient Storage With Ha /4 Socket/1 Yr Svcs Required RHEL-RS-4S-1A ● Resilient Storage
Select an operating system media kit (optional) ● RHEL 6 Media Only (Multilingual) RHEL-6 ● SLES 11 media only (multilingual) SLES-11 ● Windows Svr 2008 ST media MSWS-08-STHV-RM ● Windows Svr 2008 EN media MSWS-08-ENHV-RM ● Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) MSWS-08R2-STHV-RM ● Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) MSWS-08R2-ENHV-RM ● Windows Svr 2008 ST media R2 DC (1-8CPU, 25CAL) MSWS-08R2-DCHV-RM STEP 12: Select from a variety of value-added software.
STEP 13: Select the appropriate services. (optional) A variety of service options are available, as listed here.
● UC Support 8X5XNBD On-site CON-UCS5-C460M2 ● UC Support 8X5X4 On-site CON-UCS6-C460M2 ● UC Support 24x7x4 On-site CON-UCS7-C460M2 ● UC Support 24x7x2 On-site CON-UCS8-C460M2 Cisco Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service.
Product Notes Memory Notes ● A factory memory mirroring option is available. RAID 1 is to storage as memory mirroring is to memory. System administrators can configure their Cisco UCS C460 M2 server to maintain a mirrored copy of the information contained in memory. Note: Memory mirroring is available only when banks 1 and 2 are populated with identical DIMMs. ● There are 16 DIMM slots per CPU (eight per memory riser board).
Table 2. CPU and Memory Riser Mapping UCS C460 server has 4 processor sockets, each socket has 2 memory risers. The following table shows the placement of the CPU and their corresponding memory risers.
Figure 6. Memory Riser Board on the Cisco UCS C460 M2 Server Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes PCIe Slot Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
PCIe Slot Notes As Figure 7 shows, the Cisco UCS C460 M2 Server has 10 PCIe slots available. There are a total of 11 slots; one is a dedicated SAS riser slot. Figure 7. PCIe Slots on the Cisco UCS C460 M2 Server Table 3.
RAID Controller Notes The SAS riser card is installed at PCIe slot 11, the SAS riser slot. The SAS riser card supports 12 SAS/SATA ports when used in conjunction with the SAS Expander backplane. The SAS riser board (LSI MegaRAID SAS 9260-8i) supports the following features: ● Form factor: PCIe Low Profile (H x L) = 2.72 x 6.60 inches ● LSI SAS2108 (Liberator) ROC (RAID-On-a-Chip) Controller, at 800 MHz ● PCIe x8 card edge, also compatible with x16 lane slots, 5-Gbps or 2.
The SAS riser board (LSI MegaRAID SAS 9240-8i) supports the following features: ● Form factor: PCIe Low Profile (H x L) = 2.536 x 6.60 inches ● LSI SAS2008 PCI-Express-SAS/SATA I/O processor chip. ● PCIe x8 card edge, also compatible with x16 lane slots, 5-Gbps or 2.5-Gbps serial transfer rate ● Two internal Mini SAS 4i connectors ● Eight channels of SAS/SATA at up to 6 Gb per second ◦ SAS rates of 6.0 Gb per second and 3.0 Gb per second ◦ SATA rates of 3.0 Gb per second and 1.
Technical Specifications Physical Dimension Specifications Table 4. Physical Dimension Specifications for the Cisco UCS C460 M2Server Dimension Specification Height 6.8 in. (173.8 mm) Width 16.7 in. (424 mm) Depth 27.7 in. (704 mm) Front Clearance 3 in.(76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 6 in. (152 mm) Weight 110.
Table 6. Plug and Connector Part Numbers for the Cisco UCS C460 M2 Server Part Number Description Plug Connector CAB-9K12A-NA 125VAC 13A NEMA 5-15 PLUG NEMA 5-15P IEC60320/C15 CAB-AC-250V/13A NEMA L6-20 250V/20A IEC320/C13 PLUG NEMA L6-20 IEC60320/C13 CAB-C13-C14-JMPR RECESSED RECEPTICAL AC SS10A HS10S CAB-N5K6A-NA 200/240V 6A NEMA 6-15P IEC60320/C13 R2XXDMYMPWRCORD NO POWER CORD N/A N/A Figure 8.
Environmental Specifications Table 7. Environmental Specifications for the Cisco UCS C460 M2 Server Environment Specification Temperature operating 10°C to 35°C (50°F to 95°F) Temperature nonoperating -40°C to 70°C (-40°F to 158°F) Altitude -30 to 1,500 m (-100 to 5,000 ft.) Humidity nonoperating 95%, noncondensing at temperatures of 25°C (77°F) to 30°C (86°F) Vibration nonoperating 2.