SpecSheet Cisco UCS C200 M2 High-Density Rack-Mount Server Overview ® The Cisco UCS C200 M2 High-Density Rack-Mount Server is a high-density, two-socket, one rack-unit (1RU) ™ rack-mount server that extends the capabilities of the Cisco Unified Computing System , using Intel’s latest Xeon 5600 Series multi-core processors with 12 DIMM slots, and two PCIe slots. The UCS C200 M2 server is available in two versions: one with eight (8) 2.
Figure 2. Cisco UCS C200 M2 SFF High-Density Rack-Mount Server Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes Option Card Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Detailed Views Figure 3. Front View of the Cisco UCS C200 M2 LFF Server Front Panel Features A Slim-line 24x SATA DVD-RW D System Status LED Panel B 4 x SAS/SATA 3.
Figure 4. Front View of the Cisco UCS C200 M2 SFF Server Front Panel Features A System Status LED Panel B Optional Slim-line 24x SATA DVD-RW Contents: Overview C 8 x SAS/SATA or SSD 2.5 inch Hard Disk Drive Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes Option Card Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved.
Figure 5. Note: Detailed View of the Operator Panel on the Cisco UCS C200 M2 Server The Operator Panel replaces the Optional DVD Panel Module on the Cisco UCS C200 M2 SFF Server. When the DVD Module Panel is selected for the UCS C200 M2 SFF server, the front KVM Console Connector is not available.
Figure 6. KVM Console Connector on the Cisco UCS C200 M2 Server Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes Option Card Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Figure 7. Rear View of the Cisco UCS C200 M2 Server Rear Panel Features A 10/100 Management Port (RJ-45) E 2 x Power Supplies B Serial Port (DB9) F 2 x USB 2.
Base Unit Features Table 1.
Configuring the Cisco UCS C200 M2 Rack-Mount Server The UCS C200 M2 rack-mount server is available in either a Large Form Factor (four HDD) or Small Form Factor (eight HDD) version. One version must be selected. UCS C200 M2 LFF base server R200-1120402W UCS C200 M2 SFF base server UCSC-BSE-SFF-C200 STEP: 1 Select the CPU type. Select one or two CPUs from this list. If you choose two CPUs, they must match (you cannot choose two different CPUs for the same server).
Intel Xeon 5500 Series (LFF Base Only) ● 2.93 GHz Xeon X5570 95W CPU/8MB cache/4 cores/1333MHz N20-X00001 ● 2.66 GHz Xeon X5550 95W CPU/8MB cache/4 cores/1333MHz N20-X00006 ● 2.53 GHz Xeon E5540 80W CPU/8MB cache/4 cores/1066MHz N20-X00002 ● 2.26 GHz Xeon E5520 80W CPU/8MB cache/4 cores/1066MHz N20-X00003 ● 2.13 GHz Xeon E5506 80W CPU/4MB cache/4 cores/800MHz A01-X0113 ● 2.00 GHz Xeon E5504 80W CPU/4MB cache/4 cores/800MHz N20-X00009 ● 2.
STEP: 3 Select the RAID controller option. (optional) The default option is SATA RAID 0/1 controller (integrated on motherboard). Most customers prefer to configure their own RAID setup. Cisco can provide factory-configured RAID cards for RAID 0, 1, 5, 6, and 10 depending on the RAID card chosen and the number of drives ordered. Factory-configured RAID options are listed below each RAID card.
o RAID 5 R2XX-RAID5 Requires a minimum of three HDDs, all with identical speed and capacity o RAID 6 R2XX-RAID6 Requires a minimum of four HDDs, all with identical speed and capacity o RAID 10 R2XX-RAID10 Requires a minimum of four HDDs, all with identical speed and capacity RAID Controller Options for Small Form Factor (SFF) Configuration: ● LSI 1068E Controller-Based Mezzanine Card UCSC-RAID-SFFC200 ◦ Used on the mezzanine slot inside the UCS C200 Server ◦ Supports up to eight SAS or SATA har
RAID Controller Options for LFF and SFF Configuration: ● LSI 6G MegaRAID 9280-4i4e PCIe Card UCSC-RAID-C-4i4e ◦ Takes up one of two available PCIe slots ◦ Supports up to four internal SAS or SATA drives (no mixing) ◦ Supports external JBOD expansion ◦ 512 MB Write Cache ◦ Battery Back-Up Option Available ◦ Factory-configured RAID options o RAID 0 (Striping) R2XX-RAID0 Requires a minimum of one hard drive o RAID 1 (Mirroring) R2XX-RAID1 Requires exactly two hard drives with the same size, speed and
STEP: 4 Select the drive type. (optional) 3.5-inch Hard Disk Drive (HDD) Options for Large Form Factor (LFF) Configuration. You can select a maximum of four drives from this list: ● 500GB 6Gb SATA 7.2K RPM LFF HDD/hot plug/C200 drive sled R200-D500GCSATA03 ● 300GB 6Gb SAS 15K RPM LFF HDD/hot plug/C200 drive sled R200-D300GB03 ● 450GB 6Gb SAS 15K RPM LFF HDD/hot plug/C200 drive sled R200-D450GB03 ● 1TB 6Gb SAS 7.2K RPM LFF HDD/hot plug/C200 drive sled R200-D1TC03 ● 2TB 6Gb SAS 7.
STEP: 5 Note: For SFF Server Only Select DVD-RW (optional) UCS C200 LFF configurations all come with a DVD-RW. For the UCS C200 SFF configurations the DVD-RW is optional. Customers who select a DVD-RW for the UCS C200 SFF server will not have a front accessible KVM module. ● DVD-RW Drive for C200 SFF Server UCSC-DVD-SFF-C200 ● Control Panel for C200 SFF Server UCSC-CON-SFF-C200 STEP: 6 Select option cards. (optional) You can select a maximum of two PCIe cards.
Note: Two slots are available: one standard high/half-length x16 lane with x16 connector (PCIe G2) and one low-profile/half-length x 8 lane with x 8 connector (PCIe G2). The Cisco UCS C200 M2 server can host only two PCIe option cards (including the MegaRAID card). All option cards listed above are Low Profile/Half Length Cards. All cards above will fit in either slot, except the Cisco UCS P81E Virtual Interface Card (VIC), which requires the standard high slot.
STEP: 8 Select the power cords Selecting the option R2XX-DMYMPWRCORD will result in NO power cord being shipped with the server. You can select a maximum of two power cables from this list: ● Dummy PID for a NO power cord selection R2XX-DMYMPWRCORD ● N5000 AC Power Cable, 6A, 250V, North America, 2.5m CAB-N5K6A-NA ● N5000 AC Power Cable, 13A, 250V, North America, 2.
STEP: 9 Order a rail kit. (optional) A rail kit is not included with the Cisco UCS C200 M2 base server chassis, but you can order the following kit: ● Note: Rail Kit for C200 and C210 Rack Servers R2XX-G31032RAIL This third-generation rail kit works in racks with square holes or 10-32 round holes and is shorter than the previous generation rail kit. The new R2XX-G31032RAIL measures 23.5 inches to 36 inches. in length.
STEP: 12 Select the operating system. (optional) A variety of operating system options are available.
● Resilient Storage With Ha/2 Socket/3 Yr Svcs Required RHEL-RS-2S-3A ● Resilient Storage With Ha/4 Socket/1 Yr Svcs Required RHEL-RS-4S-1A ● Resilient Storage With Ha/4 Socket/3 Yr Svcs Required RHEL-RS-4S-3A ● Scalable File System/2 Socket/1 Yr Svcs Required RHEL-SFS-2S-1A ● Scalable File System/2 Socket/3 Yr Svcs Required RHEL-SFS-2S-3A ● Scalable File System/4 Socket/1 Yr Svcs Required RHEL-SFS-4S-1A ● Scalable File System/4 Socket/3 Yr Svcs Required RHEL-SFS-4S-3A Windows Server ●
Select an OS Media Kit. (optional) ● RHEL 6 Media Only (Multilingual) RHEL-6 ● SLES 11 media only (multilingual) SLES-11 ● Windows Svr 2008 ST media MSWS-08-STHV-RM ● Windows Svr 2008 EN media MSWS-08-ENHV-RM ● Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL) MSWS-08R2-STHV-RM ● Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL) MSWS-08R2-ENHV-RM ● Windows Svr 2008 ST media R2 DC (1-8CPU, 25CAL) MSWS-08R2-DCHV-RM STEP: 13 Select from a variety of value-added software.
STEP: 14 Select the appropriate Services. (optional) A variety of Service options are available, as listed here. Unified Computing Mission Critical Service This service delivers personalized technical account management, expedited technical support, and expert field support engineering for the Cisco Unified Computing System (UCS).
● UC Support 8X5XNBD Not on-site CON-UCS1-R200 W ● UC Support 8X5X4 Not on-site CON-UCS2-R200W ● UC Support 24x7x4 Not on-site CON-UCS3-R200W ● UC Support 24x7x2 Not on-site CON-UCS4-R200W ● UC Support 8X5XNBD On-site CON-UCS5-R200W ● UC Support 8X5X4 On-site CON-UCS6-R200W ● UC Support 24x7x4 On-site CON-UCS7-R200W ● UC Support 24x7x2 On-site CON-UCS8-R200W Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified C
Product Notes Memory Notes Figure 8. Memory notes, allowable configurations, and rules/guidelines. ● When adding DIMMs to a channel, fill Bank 1 first (the blue slots). You can run 1 or 2 DIMMs per channel. ● DIMMs within a server should all be the same type, speed, and size. Mixing different DIMMs causes the server to set the memory speed to that of the slowest installed DIMMs. ● CPU 1 supports memory mirroring only when Channels A and B are populated with identical DIMMs.
Option Card Notes Figure 9. Internal View of the Cisco UCS C200 M2 Server with PCIe and Other Slots Contents: Overview Detailed Views Base Unit Features Configuring Memory Option Cards RAID Software Services Memory Notes Option Card Notes RAID Controller Notes Physical Specs Power Specs Environmental Specs © 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
RAID Controller Notes RAID Controller Options for Large Form Factor (LFF) Configuration: The LSI MegaRAID controller can be installed in either PCIe slot on a Cisco UCS C200 M2 server. The MegaRAID card supports up to four SAS/SATA drives. ® The LSI MegaRAID card (LSI 6G MegaRAID SAS 9260-4i) supports the following features: ● Form factor: PCIe low-profile (H x L) = 2.536 x 6.60 inches ● LSI SAS2108 (Liberator) ROC (RAID-On-a-Chip) Controller, at 800MHz ● x8 PCI Express 2.
The LSISAS1064E Controller-based mezzanine card can be installed in the mezzanine slot on a Cisco UCS C200 M2 server. The mezzanine card supports up to four SAS/SATA drives. ® The LSI mezzanine card (LSI 1064E Integrated Controller) supports the following features: ● Eight PCI Express lanes at a transfer rate up to 2.
RAID Controller Options for Small Form Factor (SFF) Configuration: The LSI MegaRAID controller can be installed in either PCIe slot on a UCS C200 server. The 9260-8i MegaRAID card supports up to 8 SAS/SATA drives. ® The LSI MegaRAID card (LSI 6G MegaRAID SAS 9260-8i) supports the following features: ● Form Factor: PCIe Low Profile (H x L) = 2.72” x 6.60” ● LSI SAS2108 (Liberator) ROC (RAID-On-a-Chip) Controller, at 800MHz ● PCIe x8 card edge, also compatible with x16 lane slots, 5Gbps or 2.
The LSI SAS1068E Controller-Based Mezzanine card can be installed in the Mezzanine Slot on a UCS C200 server. The 1068E Mezzanine Card supports up to 8 SAS/SATA drives. ® The LSI Mezzanine card (LSI 1068E Integrated Controller) supports the following features: ● Supports 8 PCI Express lanes at a transfer rate up to 2.
RAID Controller Options for LFF and SFF Configurations: ® The LSI MegaRAID card (LSI 6G MegaRAID SAS 9280-4i4e) supports the following features: ● Form factor: PCIe MD2 low-profile (H x L) = 2.536 x 6.60 inches ● LSI SAS2108 6Gb/s ROC (RAID-On-a-Chip) Controller, at 800MHz ● x8 PCI Express 2.
Technical Specifications Physical Dimensions Specifications Table 2. Physical Dimension Specifications for the Cisco UCS C200 M2Server Specification Value Height 1.7 in. (4.32 cm) Width 16.92in.(43.0 cm) Depth 27.8 in. (70.60 cm) Front Clearance 3 in. (76 mm) Side Clearance 1 in. (25 mm) Rear Clearance 6 in. (152 mm) Weight 33.00 lbs (14.97 kg)* * Note: The system weight listed here is an estimate for a fully configured system and will vary depending on number of peripheral devices.
Power Specifications Table 3. Power Specifications for the Cisco UCS C200 M2 Server Parameter Minimum Nominal Maximum Start Up VAC Power Off VAC Voltage (115) 90 Vrms 100-127 Vrms 264 Vrms 85VAC +/-4VAC 75VAC +/-5VAC Voltage (220) 180 Vrms 200-240 Vrms 264 Vrms Frequency 47 Hz 50/60 Hz 63 Hz Note: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration specific power specifications, use the Cisco UCS Power Calculator: http://www.cisco.
Environmental Specifications Table 4. Environmental Specifications for the Cisco UCS C200 M2 Server Environment Specification Temperature operating 10°C to 35°C (50°F to 95°F) Temperature nonoperating -40°C to 65°C (-40°F to 149°F) Altitude operating 0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases by 1° per 300m Humidity nonoperating 5 to 93%, noncondensing Vibration nonoperating 2.