User guide

E-114
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Appendix E Real-Time Counters
VXSM-DS3-Path—Supported Real-Time Counters
cardFamily not
equal to AXSM
AND cardFamily
not equal to
AXSME AND
cardFamily not
equal to AXSMXG
AND cardFamily
not equal to PXM1E
AND cardFamily
not equal to MPSM
FEBE Count cds3FEBECount The number of Far End Block Errors(FEBE)
encountered by a T3/E3 interface.These
include frame alignment errors, multiframe
alignment errors, and C-bit parity errors.
These errors are generated by the transmitter
at the far end, and indicate that the
transmitter,cabling or the upstream node is
faulty.
cardFamily not
equal to AXSME
AND cardFamily
not equal to
AXSMXG AND
cardFamily not
equal to PXM1E
AND cardFamily
not equal to SRM
AND cardFamily
not equal to MPSM
AIS Count cds3RcvAISCount The number of times Alarm Indication
Signals(AIS) were detected. The AIS
indicates that an upstream failure has been
detected by the far end.
Table E-104 Plcp Counters—cardFcType not equal to 160
Applicability Counter Name MIB Object Name Description
All Versions CurrentBIP-8CV cds3PlcpBip8CVCurrent The number of BIP-8 code violations (CV)
encountered by the line in the current 15
minute period.
All Versions Current24HrBIP-8C
V
cds3PlcpBip8CV24HrBucket The number of BIP-8 CVs encountered by the
line in the last 24 hours.
All Versions CurrentBIP-8ES cds3PlcpBip8ESCurrent The number of BIP-8 Errored Seconds(ES)
encountered by the line in the current 15
minute period.
All Versions Current24HrBIP-8E
S
cds3PlcpBip8ES24HrBucket The number of BIP-8 ES encountered by the
line in the last 24 hour.
All Versions CurrentBIP-8SES cds3PlcpBip8SESCurrent The number of BIP-8 Severely Errored
Seconds(ES) encountered by the line in the
current 15 minute period.
All Versions Current24HrBIP-8S
ES
cds3PlcpBip8SES24HrBucket The number of BIP-8 SES encountered by the
line in the last 24 hour.
All Versions CurrentSEFs cds3PlcpSEFSCurrent The number of BIP-8 Severely Errored
Framing Seconds(SEFS) encountered by the
line in the current 15-minute period.
Table E-103 Line Alarm Statistics (continued)
Applicability Counter Name MIB Object Name Description