User guide
6-138
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Chapter6 Configuring Hardware
How Do I Configure VISM-PR Cards?
Table 6-68 Field Descriptions for the VISM-PR Line Config Tab, Physical Line Alarm Config (DSX1)
Category
Field Name Description
Setup Red Alarm
Severity
Allows you to set up the severity of a RED alarm, so that when a LOS alarm
is detected, VISM-PR will send the alarm with the appropriate severity status.
Values include:
• minor
• major
Setup RAI Alarm
Severity
Allows you to set up the severity of a RAI alarm, so that when a LOS alarm is
detected, VISM-PR will send the alarm with the appropriate severity status.
Values include:
• minor
• major
Alarm State Bitmap of the DSX1 line alarms on the VISM-PR card.
Statistical Alarm State Bitmap of the DSX1 line statistical alarms on the VISM-PR card.
Statistical Alarm
Severity
Allows you to set up the severity of statistical alarms, so that when any
statistical alarm is detected, VISM-PR will send the alarm with the
appropriate severity status. Values include:
• minor
• major
• inhibit
NE Alarm Up Count Specifies the integration counter. The local alarms are LOS and LOF. Update
the counter every 10 minutes to reach the threshold.
NE Alarm Down
Count
Specifies the integration counter. The near-end alarms are LOS and LOF.
Update the counter every 10 minutes to reach 0.
NE Alarm Threshold Determines the value to declare near-end alarm. A count of 1500 gives 2.5
seconds to declare LOS with an up count value of six.
FE Alarm Up Count Specifies the integration counter. The far-end alarms are AIS and YEL.
Update counter every 10 minutes to reach the threshold.
FE Alarm Down
Count
Specifies the integration counter. The far-end alarms are AIS and YEL.
Update counter every 10 minutes to reach 0.
FE Alarm Threshold Determines the value to declare far-end alarm. A count of 1500 gives 2.5
seconds to declare LOS with an up count value of six.