How Do I Configure VISM-PR Cards?
6.9.2.1.3 Configuring Alarm Conditioning Handling on the T1 or E1 Line
Step 1 From the Domain Explorer window, choose Configuration > MGX 8880/8850 MG > Configuration
Center.
Step 2 Under the Elements tab, within the node, double-click the DS1 line under the VISM-PR card. The Line
Config tab appears by default.
Step 3 Choose the Physical Line Alarm Config (DSX1) option from the Category drop-down arrow.
Sa4 Byte Spare bit on T1/E1 framer reserved for international standardization.
Sa5 Byte
Sa6 Byte
Sa7 Byte
Sa8 Byte
Line State Allows the line administrative state (in service and out of service) to be
persistent.
Admin State Control This control object is used to change the service state of the line from is to coos
or from coos to is. The resulting service state of the line is represented by
vismDsx1State. inService: transition vismDsx1State to is. In the course, the
MGs MGCs may get notified of this transition, e.g. in the case of MGCP
through emission of RSIPs to registered call agents according to policy.
forcefulOutOfService: Take the line out of service forcefully. This releases
any resources at the line. In the course, the MGCs may get notified of this
transition, e.g in the case of MGCP through emission of RSIPs to registered
call agents according to policy. gracefulOutOfService: Take the line out of
service gracefully. If there are no resources existing, vismDsx1State
transitions to coos immediately. If resources exist, vismDsx1State transitions
to poos thus initiating a graceful shutdown. In the course, the MGs MGCs may
get notified of this transition, e.g. in the case of MGCP through emission of
RSIPs to registered call agents according to policy.
Bearer Busy Code Used when vismTrunkConditionEnable is enabled on a line. It is a
configurable busy pattern sent out on the “Bearer” on the channels, which are
receiving remote ATM channel ID (CID) alarms. If this object is not set, it
assumes a default value of 255 for E1 and 127 for T1.
Table 6-67 Field Descriptions for the VISM-PR Specific DS1 Tab, VISM Line Config Category
(continued)