How Do I Configure VXSM Cards?
RDIV Type Specifies the type of Remote Defect Indication - Virtual Tributary/Container
(RDI-V) sent by this NE to the remote NE. Values include:
onebit—(Default) specifies 1-bit RDIV
threebit—Specifies 3-bit enhanced RDIV
RDIP Type Specifies the type of Remote Defect Indication - Path (RDI-P) sent by this NE
to the remote NE. Values include:
onebit—(default) specifies 1-bit RDIP
threebit—Specifies 3-bit enhanced RDIP
Table 6-36 Field Descriptions for the VXSM Path Config Tab, Paths Category
Field Name Description
Path Number Path number.
Enable Desired state of the interface:
up—enables the path
down—disables the path
Path Width Value that indicates the type of SONET/SDH path. For SONET, the assigned
types are the STS-Nc SPEs, where N=1, 3, 12, 24, 48, 192 and 768. STS-1 is
equal to 51.84 Mbps. For SDH, the assigned types are the STM-Nc VCs,
where N=1, 4, 16, 64, and 256.
Path Payload Specifies the payload carried by the SONET/SDH path. Values are:
ds3
vt15vc11 (DS1)
vt2vc12 (E1)
Path Status Indicates the status of the interface.
Table 6-37 Field Descriptions for the VXSM DS1/E1 Path Tab, DS1/E1 Line Info Category
Field Name Description
Admin Status Desired state of the interface.
Time Elapsed Number of seconds that have elapsed since the beginning of the near end
current error measurement period.
Valid Intervals Number of previous near end intervals for which data was collected.
Table 6-35 Field Descriptions for the VXSM Line Config Tab, Sonet Line Config Category
(continued)
Field Name Description