User guide

6-43
Cisco Media Gateway Manager 5.0 User Guide
OL-5461-02
Chapter 6 Configuring Hardware
How Do I Configure AXSM Cards?
Note The following thresholds are the same for Far End and Near End.
Table 6-19 Field Descriptions for the AXSM Line Config Tab, Sonet Path Alarm Category
Field Name Description
Alarm Severity Setting this option to major or minor raises a corresponding severity alarm
when any statistical threshold is exceeded. By default, TCA crossing does not
raise any alarm.
For alarm severity definitions, see Chapter 9, “Managing Faults.”
ESs Threshold Threshold value for Errored Seconds (ES) detection for the current 15 minute
interval, above which an alarm is generated. This threshold is the same for Far
End and Near End.
Total ESs Threshold Threshold value for Errored Seconds detection for the 24-hour interval, above
which an alarm is generated.
SESs Threshold Severely Errored Seconds threshold for the current 15 minute interval, above
which an alarm is generated.
Total SESs Threshold Severely Errored Seconds threshold for the 24 hour interval, above which an
alarm is generated.
CVs Threshold Coding Violations threshold for the current 15 minute interval, above which
an alarm is generated.
Total CVs Threshold Coding Violations threshold for the 24 hour interval, above which an alarm is
generated.
UASs Threshold Unavailable Seconds threshold for the current 15 minute interval, above which
an alarm is generated.
Total UASs Threshold Unavailable Seconds threshold for the 24 hour interval, above which an alarm
is generated.
Path Alarm State Current alarm status of the path.
Path Stat Alarm State Indicates the path stat alarm status of the interface.