How Do I Configure AXSM Cards?
Note The following thresholds are the same for Far End and Near End.
Table 6-18 Field Descriptions for the AXSM Line Config Tab, Sonet Section Alarm Category
Field Name Description
Alarm Severity Setting this option to major or minor raises a corresponding severity alarm
when any statistical threshold is exceeded.
Note For alarm severity definitions, see Chapter 9, “Managing Faults.”
ESs Threshold Threshold value for Errored Seconds detection for the current 15 minute
interval, above which an alarm is generated.
Total ESs Threshold Threshold value for Errored Seconds detection for the 24-hour interval, above
which an alarm is generated.
SESs Threshold Severely Errored Seconds threshold for the current 15 minute interval, above
which an alarm is generated.
Total SESs Threshold Severely Errored Seconds threshold for the 24 hour interval, above which an
alarm is generated.
SEFSs Threshold Severely Errored Framing Seconds threshold for the current 15 minute
interval, above which an alarm is generated.
Total SEFSs
Threshold
Severely Errored Framing Seconds threshold for the 24 hour interval, above
which an alarm is generated.
CVs Threshold Coding Violations threshold for the current 15 minute interval, above which
an alarm is generated.
Total CVs Threshold Coding Violations threshold for the 24 hour interval, above which an alarm is
generated.
Section Alarm State Current alarm status of the section.
Section Stat Alarm
State