Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
OL-23420-01
Chapter 5 Field-Replaceable Units and Region- and Country-Specific Power Cables
Replacing the Display Assembly—Part Number CTS500-32-INTDISP=
Step 8 Loosen the screws that attach the display assembly to the column and pull the display off the column.
Figure 5-6 Removing the Display From the Column
Step 9
Unpack the new display assembly.
Step 10 Put the new assembly back on the column and route the cable bundles upward behind the codec bracket.
Note Attachment of the display is the same procedure as removal, with the steps performed in reverse.
Step 11 Tighten the screws that attach the display to the column. The screws are shown in Figure 5-6.
Step 12 Place the codec back in the bracket in the display assembly and secure it with the screws you saved in
Step 5.
Step 13 Reconnect the cables. Use the tape flags or the wiring diagram on the codec as a guide.
Step 14 Use the tie-wraps to route the cables.
Correct cable routing ensures that the codec cover can be placed on the rear of the display. Therefore,
make sure that the cables do not cover the mounting holes for the codec cover, and that they do not
protrude so that you cannot attach the codec cover.
Step 15 Place the rear codec cover back on the display.
Step 16 Follow these steps to configure the new codec in Cisco Unified Communications Manager:
a. Open a browser on a computer connected to the network.
b. Access the Cisco Unified Communications Manager interface.
c. Add the Room Email ID of the previous codec to the new codec.
d. Make sure the new codec's status is registered.