Datasheet
A-18
Catalyst 6500 Series Switches Installation Guide
OL-5781-07
Appendix A Power Supply Specifications
1400 W AC-Input Power Supply
1400 W AC-Input Power Supply
The 1400 W AC-input power supply (PWR-1400-AC) can be installed in the Catalyst 6503 switch and
Catalyst 6503-E switch chassis only. Due to form factor differences, the 1400 W AC-input power supply
cannot be installed in any other Catalyst 6500 series switch chassis.
The 1400 W power supplies (see Figure A-7) do not connect directly to source AC but use power entry
modules (PEMs), located on the front of the Catalyst 6503 and Catalyst 6503-E switch chassis, to
connect the site power source to the power supply located in the back of the chassis.
The AC-input PEM (PEM-20A-AC+) (shown in Figure A-8) provides an input power connection on the
front of the router chassis to connect the site power source to the power supply.
The PEMs have an illuminated power switch, current protection, surge and EMI suppression, and filtering
functions.
Figure A-7 1400 W AC-Input Power Supply (PWR-1400-AC)
TableA-13 1300W Power Supply AC Power Cords
Locale Power Cord
Part Number
AC Source Plug Type Cordset Rating Power Cord
Reference
Illustration
Argentina CAB-7513ACR= IRAM 2073 10 A, 250 VAC Figure A-31
Australia, New Zealand CAB-7513ACA= SAA AS 3112 15 A, 250 VAC Figure A-32
Continental Europe CAB-7513ACE= CEE 7/7 16 A, 250 VAC Figure A-33
Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-34
Italy CAB-7513ACI= CEI 23-16/7 16 A, 250 VAC Figure A-35
Japan, North America CAB-7513AC= NEMA 5-20
1
1. For Japan, ask your local electrical contractor to prepare the NEMA 5-20 power plug.
20 A, 125 VAC Figure A-36
People’s Republic of
China
CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-37
South Africa CAB-7513ACSA= IEC 884-1 16 A, 250 VAC Figure A-38
Switzerland CAB-ACS-10= SEV 1011 10 A, 250 VAC Figure A-39
United Kingdom CAB-7513ACU= BS 1363
2
2. Plug contains a 13 A fuse.