Data Sheet

Page 4 of 8
Table 3. Environmental Specifications
Environmental Units Long Reach &
Extended Reach
Broadcast Tx
High-Density
Forward QAM Tx
Reverse Tx Notes
Temperature Range
Full Specs
°C
°F
-20 to +65
-4 to +149
-20 to +65
-4 to +149
-20 to +65
-4 to +149
Operational
°C
°F
-40 to +65
-40 to +149
-40 to +65
-40 to +149
-40 to +65
-40 to +149
Humidity % 0 to 95 0 to 95 0 to 95 1
Table 4. Mechanical Specifications
Physical Dimensions Units Long Reach &
Extended Reach
Broadcast Tx
High-Density
Forward QAM Tx
Reverse Tx Notes
Depth
in.
cm
9.8
24.9
8.80
22.35
9.8
24.9
Width
in.
cm
3.2
8.1
1.03
2.62
1.0
2.5
Height
in.
cm
7.6
19.3
3.48
8.84
7.6
19.3
Weight
lb
kg
6.0
2.7
0.90
0.41
3.0
1.4
Module Width
slots 3 1 1
Notes:
1. Recommended for use in non-condensing environments only.
Unless otherwise noted, specifications are based on measurements made in accordance with NCTA Practices for Measurements made on Cable
Television Systems using standard frequency assignments and are referenced to the ambient air temperature at the inlet to the Prisma II chassis.