Chassis Inputs & Outputs
EM IN/EM OUT
The EM IN and EM OUT connectors on
the connector interface panel are used
to allow TNCS element management
software to control and monitor more
than one chassis.
ALARMS IN/ALARMS OUT
These connectors allow for an ALARM
OUT ALARM IN for each module slot in
the chassis.
ICIM IN/ICIM OUT
These connectors allow one ICIM to
control and monitor modules in more
than one chassis.
RF Input Output Ports
These connections allow RF
connectivity to chassis backplane
feeding modules
Power Supply Inlets
The primary and secondary power
supplies are inserted from the front of
the chassis. The power supply
connectors mate with the factory-
installed power inlet connectors on the
backplane. The inlets differ according to
which type of power supply is installed.
Either AC or DC supplies can be
installed in the chassis when the proper
power inlets are installed
Alarms
In/Out
EM
In/Out
ICIM