Step 2: Change Chassis ID Number
1. Locate the chassis ID switch at upper right on the front panel of each
chassis. The switch can be set to any two-digit value from 00 to 99 (but
avoid setting the value to 00, as explained below).
2. Use the chassis ID switch to set each chassis ID number to a unique
value.
Note:
The chassis ID number can be changed while the chassis is under power.
However, the new ID number will not become effective until chassis power
is cycled or the ICIM2-XD is rebooted.
The chassis numbering scheme used is discretionary, except that each
interconnected chassis must have a unique ID number.
CAUTION:
Setting the chassis ID to 00 is not recommended as it causes the entity MIB to violate
RFC-2737 by creating an invalid object identifier. This may affect operation with some
management systems that use the entity MIB. In particular, attempts to access the fans
(in virtual slot 0) in chassis 00 will fail if made via serial TNCS (or ROSA-EM) or LCI.